跳转到主内容

CFBIOS-54:将BMC更新到版本(版本)之后、重新启动电源期间出现"BIOS POST Failure"(BIOS POST故障)和IPMI故障

Views:
1
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

问题描述

  • 在某些运行较旧BIOS版本的存储系统上、如果底板管理控制器(BMC)最近升级到了版本1*或更高版本、则节点无法启动、并显示"BIOS POST Failure"错误、这与IPMI与BMC通信失败相关。
  • 随后、BMC将启动到其备份固件映像。
  • 以下控制台消息指示此问题描述:

BIOS Version: 11.4
Portions Copyright (C) 2014-2018 NetApp, Inc. All Rights Reserved.
Initializing System Memory ...
Loading Device Drivers ...
Waiting for SP ...
SP failure. Resetting SP from primary FW. This can take a few minutes
Waiting for SP ...
SP failure. Resetting SP from backup FW. This can take a few minutes
Waiting for SP ...
Failed to recover SP
IPMI:Get controller FRU inventory:failed <<<<<<
Configuring Devices ...
IPMI PCI Slot Control failed. <<<<<<
...
BIOS POST Failure(s) detected: SP IPMI failure. Abort AUTOBOOT <<<<<<
LOADER-B>

 
  • BMC系统事件日志(SEL)中的以下消息指示此问题描述:

Record 314: ... [BMC.notice]: Running secondary version 11.2 <<<<<<
Record 315: ... [SysFW.notice]: SP did not respond to sync command for 332 seconds.
Record 316: ... [SysFW.notice]: Failed to recover SP
Record 317: ... [SysFW.critical]: IPMI:Get controller FRU inventory:failed <<<<<<
...
Record 320: ... [IPMI.notice]: 001a | 00 | EVT: 6fc206ff | System_FW_Status | Assertion Event, "BIOS has reset SP"
Record 321: ... [SysFW.critical]: IPMI PCI Slot Control failed. <<<<<<

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.