CFBIOS-54:将BMC更新到版本(版本)之后、重新启动电源期间出现"BIOS POST Failure"(BIOS POST故障)和IPMI故障
问题描述
- 在某些运行较旧BIOS版本的存储系统上、如果底板管理控制器(BMC)最近升级到了版本1*或更高版本、则节点无法启动、并显示"BIOS POST Failure"错误、这与IPMI与BMC通信失败相关。
- 随后、BMC将启动到其备份固件映像。
- 以下控制台消息指示此问题描述:
BIOS Version: 11.4
Portions Copyright (C) 2014-2018 NetApp, Inc. All Rights Reserved.
Initializing System Memory ...
Loading Device Drivers ...
Waiting for SP ...
SP failure. Resetting SP from primary FW. This can take a few minutes
Waiting for SP ...
SP failure. Resetting SP from backup FW. This can take a few minutes
Waiting for SP ...
Failed to recover SP
IPMI:Get controller FRU inventory:failed <<<<<<
Configuring Devices ...
IPMI PCI Slot Control failed. <<<<<<
...
BIOS POST Failure(s) detected: SP IPMI failure. Abort AUTOBOOT <<<<<<
LOADER-B>
- BMC系统事件日志(SEL)中的以下消息指示此问题描述:
Record 314: ... [BMC.notice]: Running secondary version 11.2 <<<<<<
Record 315: ... [SysFW.notice]: SP did not respond to sync command for 332 seconds.
Record 316: ... [SysFW.notice]: Failed to recover SP
Record 317: ... [SysFW.critical]: IPMI:Get controller FRU inventory:failed <<<<<<
...
Record 320: ... [IPMI.notice]: 001a | 00 | EVT: 6fc206ff | System_FW_Status | Assertion Event, "BIOS has reset SP"
Record 321: ... [SysFW.critical]: IPMI PCI Slot Control failed. <<<<<<