跳转到主内容

由于"FabricSwitchUnachable_Alert"、子系统MetroCluster和FHM-Switch报告降级

Views:
96
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
metrocluster
Last Updated:

适用场景

  • ONTAP 9
  • MetroCluster

问题描述

由于Mcc-IP集群中的"FabricSwitchUnachable_Alert"、子系统MetroCluster和"FHM-Switch"报告已降级
 
::> system health alert show
        Node: Node-n3
      Alert ID: FabricSwitchUnreachable_Alert
      Resource: Brocade_XX.YYY.ZZ.38
      Severity: Major
   Indication Time: Sat Feb 15 11:37:14 2025
      Suppress: false
     Acknowledge: false
   Probable Cause: "Brocade_XX.YYY.ZZ.38" switch is not reachable over
           the management network.
   Possible Effect: Switch "Brocade_XX.YYY.ZZ.38" cannot be monitored for
           alerts.
 Corrective Actions: 1) Ensure that the node management LIF is up by using the command "network interface show".
           2) Ensure that the switch "Brocade_XX.YYY.ZZ.38" is alive by using the command "network ping".
           3) Ensure that the switch is reachable over SNMP by
           checking its SNMP settings after logging into the
           switch.
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.