跳转到主内容

EMS会在MetroCluster FC上报告"Failover monitor:takeover disabled (unSynchronized log)"

Views:
59
Visibility:
Internal
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2008516119</a>
Specialty:
metrocluster
Last Updated:

适用场景

  • MetroCluster FC
  • ONTAP 9
  • Data ONTAP 8

问题描述

  • 系统采用MetroCluster FC配置。
  • FCVI出错、EMS报告错误"takeover disabled (unsynchronized log)"。

示例:

10/25/2020 17:23:12 SITExxxx01   ERROR         cf.fsm.takeoverByPartnerDisabled: Failover monitor: takeover of SITExxxx01 by SITExxxx02 disabled (unsynchronized log).
10/25/2020 17:23:18 SITExxxx02   ERROR         cf.fsm.takeoverByPartnerDisabled: Failover monitor: takeover of SITExxxx02 by SITExxxx01 disabled (unsynchronized log).

  • 接管将在几秒钟后自动启用。

示例:

10/25/2020 17:23:23 SITExxxx01   NOTICE        cf.fsm.takeoverByPartnerEnabled: Failover monitor: takeover of SITExxxx01 by SITExxxx02 enabled
10/25/2020 17:23:23 SITExxxx02   NOTICE        cf.fsm.takeoverByPartnerEnabled: Failover monitor: takeover of SITExxxx02 by SITExxxx01 enabled

  或

XXX XX XX:XX:42 +1000 [Node1  : cf_main: cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of Node1 disabled (unsynchronized log).
XXX XX XX:XX:42 +1000 [Node2  : cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of Node2 by Node1 disabled (unsynchronized log)

  • porterrshow在swtich上、有许多 enc out 和 disc c3。

示例:

porterrshow        :
          frames      enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy  c3timeout    pcs    uncor
       tx     rx      in    err    g_eof  shrt   long   eof     out   c3    fail    sync   sig                  tx    rx     err    err
 44:    2.7g 863.1m   0      0      0      0      0      0    443     46      0      0      8      0      0      0      0      2.6m   0
 45:  866.2m   3.6g   0      1      0      0      1      1    480      2      0      0     10      0      0      0      0      2.6m   0
 46:  309.1m   1.1g   0      0      0      0      0      0    205    367      0      0      8      0      0      0      0    742.2k   0
 47:    1.4g   1.4g   0      1      0      0      1      0    222     81      0      0      8      0      0      0      0      1.9m   0

  44  44   072c00   id    8G      Online      FC  LS E-Port  10:00:88:94:71:9f:74:24 "SITEA9000-BR620-4-01" (downstream)(Trunk master)
  45  45   072d00   id    8G      Online      FC  LS E-Port  (Trunk port, master is Port 44 )
  46  46   072e00   id    8G      Online      FC  LS E-Port  10:00:88:94:71:9f:74:24 "SITEA9000-BR620-4-01" (Trunk master)
  47  47   072f00   id    8G      Online      FC  LS E-Port  (Trunk port, master is Port 46 )

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

This is an internal KB article and its content should not be copy/pasted and shared with people outside of NetApp. Always seek Duty Manager authentication of caller for password reset requests. If you need further assistance post a question in Knowledge Xchange