适用场景

  • Data ONTAP 9.
  • MetroCluster
  • Cisco SAN交换机
  • Brocade SAN交换机

问题描述

  • 在确定MetroCluster状态时、会观察到LIF警告:

::> metrocluster check run
::> metrocluster check show
  Last Checked On: dd/mm/yyyy hh:mm:ss

Component           Result
------------------- ---------
nodes               ok
lifs                warning
config-replication  ok
aggregates          ok
clusters            oK

  • 进一步的分析表明,网络结构名称与问题描述相关

::> metrocluster check lif show
Vserver         LIF        Protocol    Failure
--------------  ---------  ---------   ----------  ---------------
Vserver1                       FCP01      fcp         There are no ports on node "Node1" connected to fabric "xx:xx:xx:xx:xx:xx:xx:xx" in the destination cluster. Cannot place FC LIF "FCP01" hosted on the source cluster port "0e" of "CNA" adapter type for Vserver "Vserver1-mc".
Vserver1                       FCP02      fcp         There are no ports on node "Node1" connected to fabric "xx:xx:xx:xx:xx:xx:xx:xx" in the destination cluster. Cannot place FC LIF "FCP02" hosted on the source cluster port "0h" of "CNA" adapter type for Vserver "Vserver-mc".

Vserver2                       FCP03    fcp                   No ports found on MetroCluster DR node "Node2" connected to fabric with fabric name "xx:xx:xx:xx:xx:xx:xx:xx"
Vserver2                       FCP04    fcp                   No ports found on MetroCluster DR node "Node2" connected to fabric with fabric name "xx:xx:xx:xx:xx:xx:xx:xx

  • 如果前端交换机是Brocade交换机,请通过运行来确认LSAN是否已配置 nsshow
[...] N 2c1001; 3;20:07:xx:xx:xx:xx:xx:xx;20:0a:xx:xx:xx:xx:xx:xx; 0x00000003 SCR: Fabric-Detected Nx-Port-Detected FC4s: FCP PortSymb: [88] "NetApp FC Target Port (LPe16000) SVMNAME_FC:nodename_fc_lif_2" NodeSymb: [35] "NetApp Vserver SVMNAME_FC" Fabric Port Name: 20:10:xx:xx:xx:xx:xx:xx Permanent Port Name: 50:0a:xx:xx:xx:xx:xx:xx Device type: NPIV Target Port Index: 16 Share Area: No Redirect: No Partial: No LSAN: Yes [...]

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.