在连接到网络结构名称为 xx : xx : xx : xx : xx : xx : xx : xx : xx : xx : xx 的 MetroCluster DR 节点上未找到端口
适用场景
- Data ONTAP 9.
- MetroCluster
- Cisco SAN交换机
- Brocade SAN交换机
问题描述
- 在确定MetroCluster状态时、会观察到LIF警告:
::> metrocluster check run
::> metrocluster check show
Last Checked On: dd/mm/yyyy hh:mm:ss
Component Result
------------------- ---------
nodes ok
lifs warning
config-replication ok
aggregates ok
clusters oK
- 进一步的分析表明,网络结构名称与问题描述相关:
::> metrocluster check lif show
Vserver LIF Protocol Failure
-------------- --------- --------- ---------- ---------------
Vserver1 FCP01 fcp There are no ports on node "Node1" connected to fabric "xx:xx:xx:xx:xx:xx:xx:xx" in the destination cluster. Cannot place FC LIF "FCP01" hosted on the source cluster port "0e" of "CNA" adapter type for Vserver "Vserver1-mc".
Vserver1 FCP02 fcp There are no ports on node "Node1" connected to fabric "xx:xx:xx:xx:xx:xx:xx:xx" in the destination cluster. Cannot place FC LIF "FCP02" hosted on the source cluster port "0h" of "CNA" adapter type for Vserver "Vserver-mc".
Vserver2 FCP03 fcp No ports found on MetroCluster DR node "Node2" connected to fabric with fabric name "xx:xx:xx:xx:xx:xx:xx:xx"
Vserver2 FCP04 fcp No ports found on MetroCluster DR node "Node2" connected to fabric with fabric name "xx:xx:xx:xx:xx:xx:xx:xx
- 如果前端交换机是Brocade交换机,请通过运行来确认LSAN是否已配置
nsshow
:
[...] N 2c1001; 3;20:07:xx:xx:xx:xx:xx:xx;20:0a:xx:xx:xx:xx:xx:xx; 0x00000003 SCR: Fabric-Detected Nx-Port-Detected FC4s: FCP PortSymb: [88] "NetApp FC Target Port (LPe16000) SVMNAME_FC:nodename_fc_lif_2" NodeSymb: [35] "NetApp Vserver SVMNAME_FC" Fabric Port Name: 20:10:xx:xx:xx:xx:xx:xx Permanent Port Name: 50:0a:xx:xx:xx:xx:xx:xx Device type: NPIV Target Port Index: 16 Share Area: No Redirect: No Partial: No LSAN: Yes [...]