跳转到主内容

当系统处于切换状态时、 MetroCluster 检查命令会显示警告

Views:
32
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

适用于

  • ONTAP 9.1 及更早版本

问题

当在切换状态下运行 MetroCluster check 命令时、某些检查会返回警告:

ClusterA::> metrocluster  check show
Last Checked On: 4/21/2016 07:34:32

Component       Result
------------------- ---------
nodes         warning
lifs         ok
config-replication  warning
aggregates      ok
clusters       ok
5 entries were displayed.

ClusterA::> metrocluster check node show
Last Checked On: 4/21/2016 07:34:32

Node          Check                 Result
--------------------- ------------------------------------ ---------
ClusterA-01
            node-reachable             ok
            metrocluster-ready           ok
            local-ha-partner            ok
            ha-mirroring-on            ok
            ha-mirroring-op-state         ok
            symmetric-ha-relationship       ok
            remote-dr-partner           ok
            dr-mirroring-on            warning
            dr-mirroring-op-state         warning
            symmetric-dr-relationship       ok
            remote-dr-auxiliary-partner      ok
            symmetric-dr-auxiliary-relationship  ok
            storage-failover-enabled        ok
            has-intercluster-lif          ok
            node-object-limit           ok
            automatic-uso             not-applicable

ClusterA::> metrocluster check config-replication  show -instance
         Enabled: true
         Running: true
     Recovery Steps: -

    Remote Heartbeat: ok
   Last Heartbeat Sent: 4/21/2016 08:20:32
Last Heartbeat Received: 4/21/2016 08:19:57
     Recovery Steps: -

     Storage Status: ok
     Storage In Use: Cluster-wide Volume: MDV_CRS_1fa20d6af0df11e5942100a0985bb98a_A
     Storage Remarks: -
     Recovery Steps: -

     Vserver Streams: warning
     Recovery Steps: Run the "metrocluster vserver show" command for more details.

     Cluster Streams: warning
     Recovery Steps: Contact technical support for assistance.

 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.