跳转到主内容

使用光缆在 SAS 端口中禁用了各个 PHY

Views:
30
Visibility:
Internal
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • 分散的 MetroCluster
  • ONTAP 9
  • ONTAP 8

问题描述

::> run -node <node_name> -command sysconfig -a

(...)
slot 0: SAS Host Adapter 0a (PMC-Sierra PM8001 rev. C, SAS, <UP>)
   Firmware rev:       01.12.09.00
   Base WWN:           5:00a098:0039bc1:c0
   Phy State:          [0] Disabled 
                       [1] Enabled, 6.0 Gb/s
                       [2] Enabled, 6.0 Gb/s
                       [3] Enabled, 6.0 Gb/s
   QSFP Vendor:        FINISAR CORP   
   QSFP Part Number:   332-00335+A0   
   QSFP Type:          Optical (850nm VCSEL) 0m ID:00 
   QSFP Serial Number: XWB132A
 (...)

::> run -node local -command storage show shelf -a

(...)
Shelf name: 0a.shelf11
Shelf id: 11
Channel: 0a
Module: B
Shelf UID: 50:0a:09:80:03:8d:5e:87
Shelf S/N: SHFHU1652000238
Term switch: N/A
Shelf state: ONLINE
Module state: OK

Partial Path Link Invalid Running Loss Phy CRC Phy
Disk Port Timeout Rate DWord Disparity Dword Reset Error Change
Id State Value (ms) (Gb/s) Count Count Count Problem Count Count
--------------------------------------------------------------------------------------------
[SQR0] NO SIGNAL 7 NA 0 0 0 0 0 23
[SQR1] OK 7 6.0 0 0 0 0 0 26
[SQR2] OK 7 6.0 0 0 0 0 0 26
[SQR3] OK 7 6.0 0 0 0 0 0 26
[CIR4] OK 7 6.0 0 0 0 0 0 1
(...)

 