拆除或更换交换机后持续存在的交换机运行状况警报
适用于
- ONTAP
- 集群交换机
问题描述
- 删除后,集群交换机存在交换机健康警报
Cluster::> system health alert show
Node: Cluster-02
示例:
Alert ID: SwitchSSHAccess_Alert
Alert ID: SwitchInfoUpdateFailure_Alert
Resource: Old-Cluster-SW2 (XX:XX:XX:XX:XX:XX)
- 已删除交换机的健康警报
.
::*> system health subsystem show Subsystem Health ----------------- ------------------ SAS-connect ok Environment ok Memory ok Service-Processor ok Switch-Health degraded CIFS-NDO ok Motherboard ok IO ok MetroCluster ok MetroCluster_Node ok FHM-Switch ok FHM-Bridge ok SAS-connect_Cluster ok 13 entries were displayed.
::*> system health subsystem show -subsystem switch-Health Subsystem: Switch-Health Health: degraded Initialization State: initialized Number of Outstanding Alerts: 4 Number of Suppressed Alerts: 0 Node: switch1 Subsystem Refresh Interval: 5m
- 交换机被删除后不再显示
- ONTAP 9.8 及更高版本 -
::>system switch ethernet delete -device Old-Cluster-SW2
-
::>system switch ethernet show
Error: There are no entries matching your query.
- ONTAP 9.7 及更低版本 -
::>system cluster-switch delete -device Old-Cluster-SW2
::>system cluster-switch show
Error: There are no entries matching your query.
- ONTAP 9.8 及更高版本 -