跳转到主内容

CSHM无法监控NVIDIA交换机、原因是型号不受支持

Views:
35
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • 集群交换机运行状况监控器(CSHM)
  • 集群网络交换机 型号NVIDIA MSN2100-CB2FC

问题描述

  • 系统中会显示以下运行状况警报:

::> system health alert show
        Node: CLUSTER-NODE01
      Alert ID: SwitchLinkDiscoveryProtocol_Alert
      Resource: CLUSTER-SW02
      Severity: Minor
   Indication Time: Wed Mar 13 15:15:12 2024
      Suppress: false
     Acknowledge: false
   Probable Cause: The ethernet switch is using an unsupported link
           discovery protocol.
   Possible Effect: The change of the link discovery protocol on the
           switch is not supported. The connected device will not
           appear in link layer discovery commands.
Corrective Actions: Revert the discovery protocol change on the switch.

        Node: CLUSTER-NODE01
      Alert ID: UnsupportedSwitch_Alert
      Resource: CLUSTER-SW02
      Severity: Major
   Indication Time: Wed Mar 13 15:15:12 2024
      Suppress: false
     Acknowledge: false
   Probable Cause: Unsupported Ethernet switch is detected.
   Possible Effect: Communication problems and network connectivity issues
           occur.
 Corrective Actions: Unsupported Ethernet switch "CLUSTER-SW02
           (10:XX:XX:XX:XX:d8)" found. Connect a supported
           Ethernet switch to the network.

  • 报告受影响的集群网络交换机为 Unsupported Model 、并监控其他管理交换机:​​​​​​

CLUSTER::> system switch ethernet show
Switch            Type         Address      Model
--------------------------- ------------------ ---------------- ---------------
CLUSTER-SW02 
               cluster-network   174.XX.X.19    OTHER
   Serial Number: Unknown
    Is Monitored: true
       Reason: Unsupported Model
  Software Version: Cumulus Linux version 4.4.3 running on Mellanox
           Technologies Ltd. MSN2100
   Version Source: LLDP

Mgmt-sw01 
              management-network 172.XX.XX.12    OTHER
   Serial Number: Unknown
    Is Monitored: false
       Reason: Monitoring Disabled by Default
  Software Version: unknown
   Version Source: CDP/ISDP

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.