适用场景

  • 集群网络交换机— CN1610
  • ONTAP 8
  • ONTAP 9

问题解答

您可以通过观察风扇状态,电源状态和温度来监控交换机的物理状态。此处,以下信息涵盖了以温度为单位的温度阈值。

温度传感器和功率级别每 30 秒读取一次。风扇速度也会根据温度状态级别进行更新。

严重:

  • 温度过高:

如果温度传感器达到 61C, 某个计时器,则会启动计时器,并向管理员发出警告,同时 ALERT 会记录一条级别消息并显示消息 "Critical temperature reading" 。此计时器将在两分钟后过期。如果温度降至 60C or below,计时器,则计时器将停止。计时器过期后,系统将通过断电关闭。

  • 温度过低:

如果温度传感器达到 0C, 某个计时器,则会启动计时器,并向管理员发出警告,同时 ALERT 会记录一条级别消息并显示消息 "Critical temperature reading" 。此计时器将在两分钟后过期。如果温度高于 0C,则计时器将停止。计时器过期后,系统将通过断电关闭。

  • 警告阈值:

温度升高 54C至注释:温度降至 49 或低于之前,它不会保持警告状态。这是为了减少 NORMAL WARNING 状态之间的振动。因此,温度 50-53C 可能会显示 NORMAL or WARNING "

The following example displays normal output for the "show environment" command: (switch_name) #show environment Temp (C)....................................... 40 Fan Speed, RPM................................. 9300 Fan Duty Level................................. 75% Temperature traps range: 0 to 60 degrees (Celsius) Temperature Sensors: Unit Sensor Description Temp (C) State Max_Temp (C) ---- ------ ---------------- ---------- -------------- -------------- 1 1 CPU & SWITCH 40 Normal 48 1 2 Left PHY's 40 Normal 42 1 3 Right PHY's 0 Warning 46

追加信息

无法修改此阈值。

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.