跳转到主内容

由于重新启动环路、cn1610缺少冗余配置

Views:
2
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2009520825</a>
Specialty:
HW
Last Updated:

适用场景

  • ONTAP 9
  • CN1610集群网络交换机

问题描述

  • CN1610集群交换机丢失。
  • 交换机运行状况降级、 系统运行状况警报显示以下内容:

Node: node-01
Resource: cluster
Severity: Major
Indication Time: Mon Mar 27 14:39:25 2023
Suppress: false
Acknowledge: false
Probable Cause: Redundant configuration is missing for cluster
switches.

Node: node-01
Resource:  Link Aggregate 1
Severity: Major
Indication Time: Mon Mar 27 18:05:47 2023
Suppress: false
Acknowledge: false
Probable Cause: The cable used to connect switch "sw1/ Link
Aggregate 1" to the ISL port might be faulty.

  • 事件日志中会报告以下警报:

[node-01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterSwitchMissing_Alert , Alerting Resource = Sw1 raised by monitor ethernet-switch

[node-01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterIfIslDownWarn_Alert , Alerting Resource = sw2/ Link Aggregate 1 raised by monitor ethernet-switch

  • 在ONTAP的集群交换机运行状况监控器中看不到该交换机
  • 连接到交换机的所有端口均已关闭。
  • 连接到交换机的控制台会显示以下内容:

The system is restarting due to inconsistent state.

  • 重新启动不会解决问题描述问题。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.