由于重新启动环路、cn1610缺少冗余配置
适用场景
- ONTAP 9
 - CN1610集群网络交换机
 
问题描述
- CN1610集群交换机丢失。
 - 交换机运行状况降级、 系统运行状况警报显示以下内容:
 
Node: node-01
 Resource: cluster
 Severity: Major
 Indication Time: Mon Mar 27 14:39:25 2023
 Suppress: false
 Acknowledge: false
 Probable Cause: Redundant configuration is missing for cluster
 switches.
Node: node-01
 Resource:  Link Aggregate 1
 Severity: Major
 Indication Time: Mon Mar 27 18:05:47 2023
 Suppress: false
 Acknowledge: false
 Probable Cause: The cable used to connect switch "sw1/ Link
 Aggregate 1" to the ISL port might be faulty.
- 事件日志中会报告以下警报:
 
[node-01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterSwitchMissing_Alert , Alerting Resource = Sw1 raised by monitor ethernet-switch
[node-01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterIfIslDownWarn_Alert , Alerting Resource = sw2/ Link Aggregate 1 raised by monitor ethernet-switch
- 在ONTAP的集群交换机运行状况监控器中看不到该交换机
 - 连接到交换机的所有端口均已关闭。
 - 连接到交换机的控制台会显示以下内容:
 
The system is restarting due to inconsistent state.
- 重新启动不会解决问题描述问题。