跳转到主内容

由于端口通道D-Disable和关闭、集群网络已降级、总数据包丢失

Views:
5
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2009515405</a>
Specialty:
hw
Last Updated:

适用场景

  • 集群网络交换机(CNS) NetApp CN1610
  • 运行1.3.0.2版的FastPath

问题描述

  • 个"HA Group Notification (CLUSTER NETWORK DEGRADED)"警报
  • 在一个交换机中禁用端口通道3/1: 

(Switch-01)#show port all
                Admin    Physical   Physical   Link   Link   LACP   Actor
    Intf    Type   Mode    Mode     Status    Status Trap   Mode   Timeout
    --------- ------ --------- ---------- ---------- ------ ------- ------ --------
    ...
    0/13    PC Mbr Enable   10G Full   10G Full   Up    Enable  Enable long
    0/14    PC Mbr Enable   10G Full   10G Full   Up    Enable  Enable long
    0/15    PC Mbr Enable   10G Full   10G Full   Up    Enable  Enable long
    0/16    PC Mbr Enable   10G Full   10G Full   Up    Enable  Enable long
   3/1        D-Disable             Down   Disable N/A   N/A
    3/2        Enable              Down   Disable N/A   N/A

  • 端口未处于活动状态:

(Switch-01) #show port-channel all
    Log.   Channel            Adm.    Mbr   Device/     Port    Port
    Intf   Name       Min  Link   Mode Type Ports  Timeout     Speed    Active
    ------- --------------- ---- ------ ---- ---- ------ ------------- --------- -------
    3/1    ISL-LAG      1   Down   Dis. Stat 0/13   actor/long   10G Full  False
                              partner/long
                           0/14   actor/long   10G Full  False
                              partner/long
                           0/15   actor/long   10G Full  False
                              partner/long
                           0/16   actor/long   10G Full  False
                              partner/long

  • 但端口通道和ISL在配对系统中运行正常: 

(Switch-02) #show port all
                Admin    Physical   Physical   Link   Link   LACP   Actor
    Intf    Type   Mode    Mode     Status    Status Trap   Mode   Timeout
    --------- ------ --------- ---------- ---------- ------ ------- ------ --------
    ...
    0/13    PC Mbr Enable   10G Full        Down   Enable  Enable long
    0/14    PC Mbr Enable   10G Full        Down   Enable  Enable long
    0/15    PC Mbr Enable   10G Full        Down   Enable  Enable long
    0/16    PC Mbr Enable   10G Full        Down   Enable  Enable long
   3/1        Enable              Down   Disable N/A   N/A
    3/2        Enable              Down   Disable N/A   N/A
(Switch-02) #show port-channel all
    Log.   Channel            Adm.    Mbr   Device/     Port    Port
    Intf   Name       Min  Link   Mode Type Ports  Timeout     Speed    Active
    ------- --------------- ---- ------ ---- ---- ------ ------------- --------- -------
    3/1    ISL-LAG      1   Up    En.  Stat 0/13   actor/long   10G Full  True
                              partner/long
                           0/14   actor/long   10G Full  True
                              partner/long
                           0/15   actor/long   10G Full  True
                             partner/long
                           0/16   actor/long   10G Full  True
                              partner/long

  • 集群Ping-cluster只会出现"故障"、集群LIF会通过ISL "跨越"两个交换机

::> set advanced
::*> cluster ping-cluster -node <node_name>

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.