SwitchSNMPCommunication _Alert报告了NVIDIA集群交换机
适用场景
- NVIDIA集群交换机SN2100
- ONTAP 9
- 4节点MCC IP
问题描述
- ONTAP显示SwithSNMPCommunication警报、如下所示:
Cluster::> system health alert show Node: Cluster-01 Alert ID: SwitchSNMPCommunication_Alert Resource: cluster-switch01 Severity: Major Indication Time: Fri Aug 16 13:41:11 2024 Suppress: false Acknowledge: false Probable Cause: SNMP communication from the node to the ethernet switch has failed repeatedly. Invalid SNMP settings are configured with ONTAP Switch Health Monitoring or on the Ethernet switch. Possible Effect: Ethernet switch communication problems and accessibility issues. Corrective Actions: 1) Check the SNMPv2c community or SNMPv3 username on the Ethernet switch to verify that the expected community string or username is configured. To view the expected community string or username, run the "system switch ethernet show -snmp-config" command. 2) (SNMPv3) Verify that the SNMPv3 credentials are present within ONTAP. To view the established SNMP logins, run the "security login show -application snmp" command. If a custom engine-id was provided for the SNMPv3 user, ensure it is same as that of the remote switch.
- 在AutoSupport日志中(cshM-switch-config.XML)
CSHM-SWITCH-CONFIG.XML Device Name: cluster-switch01 Software Version Cumulus Linux version: 5.4.0 Reference Config File Version: NA SNMP Version: SNMPv2c Switch Monitoring Status: false Reason For Not Monitoring: Invalid SNMP Settings
- 这些交换机会在两个集群上报告相同的行为