跳转到主内容

在节点关闭事件期间报告SwitchIlIfDownWarn_Alert

Views:
Visibility:
Public
Votes:
0
Category:
aff-series<a>2010109223</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • Cisco集群交换机

问题描述

SwitchIslIfDownWarn_Alert 在节点关闭期间、节点报告:

Node: node-05
Alert ID: SwitchIslIfDownWarn_Alert
Resource: port-channel1
Severity: Major
Indication Time: Fri Jul 26 08:00:36 2024
Suppress: false
Acknowledge: false
Probable Cause: The cable attached to the ISL port "netappsw1(XXXXX)/port-channel1" with the description of "" might be faulty. For the port-channel, please check each individual link.
Possible Effect: Inter- or Intra- cluster redundancy might be lost.
Corrective Actions: 1) Check whether the cable is fully inserted into the interface port on both ends.
                    2) Reconnect the ISL port using another cable. After reconnecting it, verify whether the link of the ISL port is up by executing the commands per the switch configuration guide or by checking whether the Link status LED is on.


 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.