SwitchFanNotPresent_Alert针对Cisco Nexus 3232C提出
适用场景
- Cisco Nexus 3232c集群网络交换机
- ONTAP 9
问题描述
SwitchFanNotPresent_Alert
针对Cisco Nexus 3232C提出- 交换机PSU LED以恒定速率呈绿色闪烁
- 已重新拔插PSU
- 交换机控制台/日志上的事件
Dec 23 14:02:52 %PLATFORM-5-PS_STATUS PowerSupply 1 current-status is PS_SHUT Reason:FAULT/ALARM
Dec 23 14:02:52 %PLATFORM-2-PS_FAIL Power supply 1 failed or shut down (Serial number DCC2243XXXX)
Dec 23 14:02:52 %PLATFORM-5-PS_FOUND Power supply 2 found (Serial number DCC2243XXXX)
Dec 23 14:02:52 %PLATFORM-2-PS_OK Power supply 2 ok (Serial number DCC2243XXXX)
Dec 23 14:02:52 %PLATFORM-5-PS_STATUS PowerSupply 2 current-status is PS_OK
Dec 23 14:02:52 %PLATFORM-2-PS_FANOK Fan in Power supply 2 ok
Dec 23 14:02:52 %PLATFORM-2-PS_ABSENT Power supply 1 is absent/shutdown, ps- redundancy might be affected
Dec 23 14:02:52 %PLATFORM-2-PS_RED_MODE_CHG Power supply operational redundancy mode changed to non- redundant