跳转到主内容

错误: 100G 光纤收发器不支持 10g-4x 的分支映射

Views:
10
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • Cisco Nexus ( NX ) 3232C 集群网络交换机
  • 参考配置文件( RCF )
 

问题描述

interface Ethernet1/30
interface Ethernet1/31
interface Ethernet1/32
interface Ethernet1/33
interface Ethernet1/34
 

 

  • 交换机日志错误:
cs2# copy Nexus-3232C-RCF-v1.8-Cluster-Breakout.txt running-config ec ho-commands
`cs2# config terminal`
`cs2(config)# banner motd #`
`cs2(config)# interface breakout module 1 port 1-3 map 10g-4x`
Error: Breakout map of 10g-4x is not supported on a 100G optic transceiver
...
...

`cs2(config)# interface e1/1/1-4, e1/2/1-4, e1/3/1-4, e1/4/1-4, e1/5/1-4, e1/6/1-4, e1/7-30, e1/33-34`
                                                                                                   ^
Invalid range at '^' marker.
`cs2(config)# inherit port-profile CLUSTER`
               ^
% Invalid command at '^' marker.
`cs2(config)# priority-flow-control mode auto`
...
...
 
  • 错误将持续到 RCF 行完成:
% Invalid command at '^' marker. 
`cs2# end`
`cs2# end`
Copy complete, now saving to disk (please wait)...
Copy complete.
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.