跳转到主内容

由于IP地址不正确、无法访问Cisco集群交换机

Views:
7
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2009年566357</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • FAS/AFA系统
  • Cisco集群交换机

问题描述

  • 未监控此Cisco集群交换机、因为无法访问此IP地址:
ClusterA::> system switch ethernet show
Switch            Type         Address      Model
--------------------------- ------------------ ---------------- ---------------
switch_A_1(xxxxxxxxxxx)    cluster-network   10.1.1.X      NX3132V
   Serial Number: xxxxxxxxxxx
    Is Monitored: false 
       Reason: IP address not reachable
  Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 7.0(3)I4(1)
   Version Source: CDP
  • 事件日志中报告以下警报:

[Node-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchCommunityString_Alert[switch_A_1(xxxxxxxxxxx)].

  • 无法通过ping和SSH访问集群交换机的IP地址。
  • 交换机运行状况已降级:

ClusterA::> system health subsystem show
Subsystem      Health
----------------- ------------------
SAS-connect     ok
Environment     ok
Memory       ok
Service-Processor ok
Switch-Health    degraded
CIFS-NDO      ok
Motherboard     ok
IO         ok
MetroCluster    ok
MetroCluster_Node ok
FHM-Switch     ok
FHM-Bridge     ok
SAS-connect_Cluster ok
13 entries were displayed.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.