跳转到主内容
NetApp Knowledge Base site will be down for 3 hours between Oct 26, 23:59 PST and Oct 27, 02:59 PST, for system maintenance and infrastructure update.

Brocade交换机的ISL端口上报告区域冲突

Views:
30
Visibility:
Public
Votes:
1
Category:
ontap-9
Specialty:
san
Last Updated:

适用场景

  • Brocade交换机
  • ISL E端口

问题描述

  • 维护电源后、switch show输出会在ISL端口上显示分段和分区冲突:
switchshow :
0  0  123456  id   16G   Online    FC  LE E-Port  segmented,10:xx:xx:xx:xx:xx:xx:xx (zone conflict)
  • switch show输出显示 了ISL端口的分段和分区冲突、而未执行任何活动:

21  21   011500   id   N16    Online    FC  E-Port  segmented,10:0x:dx:1x:cc:8b:50:6x (zone conflict)

  • errdump 显示区域冲突警告:
errdump -a :
2022/12/15-15:57:19, WARNING, switchA, port 0, Zone conflict.
  • Duplicate entries in zone 错误转储中报告错误、即使清除重复分区、问题描述也会持久存在:

2024/01/04-18:57:06, [ZONE-1010], 113846, FID 128, WARNING, DCCFxB2xASUxFx, Duplicate entries in zone (IBM_V70x0_1_Nx_P1_DCFINDBTxxT_UAT_Hx02) specification

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • 这篇文章对您有帮助吗?