跳转到主内容

无法通过 SSH 和 WebTools 访问交换机

Views:
24
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用于

  • Brocade (G620)
  • Brocade (G720)

问题描述

  • 无法通过 SSH 或 Web Tools 访问交换机
  • Ping 交换机 IP 成功
  • 通过串行控制台连接到交换机时,输出文件系统错误:
error on file open (5): /etc/fabos/config/vf-conf
000: EXT4-fs error (device sda1): __ext4_find_entry:1531: inode #931: comm webd: reading directory lblock 0
webd -S fcsw execl failed errno: 5 errstr:Input/output error
000: EXT4-fs error (device sda1): __ext4_find_entry:1531: inode #931: comm webd: reading directory lblock 0
error on file open (5): /etc/fabos/config/vf-conf
001: EXT4-fs error (device sda1): __ext4_find_entry:1531: inode #931: comm ftcd: reading directory lblock 0
webd -S fcsw execl failed errno: 5 errstr:Input/output error
001: EXT4-fs error (device sda1): __ext4_find_entry:1531: inode #52: comm syslog-ng: reading directory lblock 0

2025/07/26-21:10:44 (HKT), [SEC-3089], 9550, FID 128, ERROR, pedsswt004, Detected incorrect configuration in authentication configuration. Error: existing config does not match authspec mode
EXT4-fs error (device sda1): ext4_lookup:1588: inode #7297: comm snmpd: deleted inode referenced: 9382
EXT4-fs error (device sda1): ext4_lookup:1588: inode #7297: comm crond: deleted inode referenced: 260

  • 开关电源循环后问题仍然存在
  • 由于安全引导而无法更改引导分区:
=> printenv
Unsupported command 'printenv' in Secure Boot Mode
=> setenv
Unsupported command 'setenv' in Secure Boot Mode

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.