  • FC Metrocluster
  • Brocade G610 FC 交换机

问题描述

  • 经常在 EMS 日志中接收以下警报(每天多次)
HA Group Notification (Health Monitor process schm: FabricSwitchUnreachable_Alert[1000xxxxxxxxxxxx]) ALERT
HA Group Notification (Health Monitor process nchm: InterconnectAdapterOfflineAlert[2100xxxxxxxxxxxx]) ALERT
HA Group Notification (Health Monitor process nchm: StorageFCAdapterFault_Alert[1000xxxxxxxxxxxx]) ALERT
HA Group Notification (Health Monitor process schm: NoISLPresentAlert[1000xxxxxxxxxxxx]) ALERT
 
  • Storage bridge show 显示连接到单个 FC 交换机的两个桥的错误

::> storage bridge show
                    Is     Monitor Managed                         Is Bridge
Bridge          Symbolic Name Monitored Status  By    Vendor Model         Bridge WWN     Secure
------------------------ ------------- --------- ------- ------- ------ --------------------- ----------------  ---------
ATTO_2000XXXXXXXXXXXX   bridge_a_2
                    true    error  in-band Atto  FibreBridge 7600N   2000XXXXXXXXXXXX  false
ATTO_2000XXXXXXXXXXXX   bridge_b_1
                    true    ok    in-band Atto  FibreBridge 7600N   2000XXXXXXXXXXXX  false
ATTO_2000XXXXXXXXXXXX   bridge_b_2
                    true    error  in-band Atto  FibreBridge 7600N   2000XXXXXXXXXXXX  false
ATTO_2000XXXXXXXXXXXX   bridge_a_1
                    true    ok    in-band Atto  FibreBridge 7600N   2000XXXXXXXXXXXX  false
4 entries were displayed.

  • 具有 error-text-list 的存储网桥显示输出
::> storage bridge show -fields error-text-list
name error-text-list
--------------------- ---------------
ATTO_2000XXXXXXXXXXXX -
ATTO_2000XXXXXXXXXXXX "ATTO_2000XXXXXXXXXXXX(2000XXXXXXXXXXXX):FC_PORT_2 is Offline."
ATTO_2000XXXXXXXXXXXX -
ATTO_2000XXXXXXXXXXXX "ATTO_2000XXXXXXXXXXXX(2000XXXXXXXXXXXX):FC_PORT_2 is Offline."
4 entries were displayed.
 
 
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.