交换机端口的磁盘 C3 和 C3 超时数量较多
适用场景
- Brocade 交换机上的端口
问题描述
- 许多
disc c3
和c3 timeout
位于porterrshow
中。
porterrshow :
CURRENT CONTEXT -- 1 , 20
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err
0: 2.1g 1.1g 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
1: 4.1g 298.6m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
2: 547.1m 151.6m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
3: 350.2m 135.9m 0 0 0 0 0 0 0 133 1 0 1 0 0 133 0 0
4: 737.0m 946.5m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
5: 910.2m 342.5m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
6: 323.4m 965.5m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
sfpshow
对于报告错误的端口、此端口的Tx (Transmit)功率过低
Alarm Warn low high low high Temperature: 34 Centigrade -5 85 0 75 Current: 10.492 mAmps 2.500 12.000 2.000 11.500 Voltage: 3308.4 mVolts 3000.0 3600.0 3100.0 3500.0 RX Power: -2.6 dBm (548.6uW) 31.6 uW 1258.9 uW 31.6 uW 794.3 uW TX Power: -7.9 dBm (161.8 uW) 125.9 uW 1258.9 uW 251.2 uW 794.3 uW