报告Brocade X7交换机上的交换机和核心刀片式服务器出现故障
适用场景
Brocade X7交换机
问题描述
- 在slotshow输出下、交换机/端口和核心刀片显示为故障
/fabos/cliexec/slotshow -m:
Slot Blade Type ID Model Name Status
--------------------------------------------------
1 CP BLADE 220 CPX7 ENABLED
2 CP BLADE 220 CPX7 ENABLED
3 SW BLADE 218 FC32-X7-48 ENABLED
4 SW BLADE 218 FC32-X7-48 FAULTY (90)
5 SW BLADE 218 FC32-X7-48 ENABLED
6 SW BLADE 218 FC32-X7-48 ENABLED
7 CORE BLADE 215 CR64-8 FAULTY (21)
8 CORE BLADE 215 CR64-8 ENABLED
9 SW BLADE 218 FC32-X7-48 ENABLED
10 SW BLADE 218 FC32-X7-48 ENABLED
11 SW BLADE 218 FC32-X7-48 ENABLED
12 SW BLADE 218 FC32-X7-48 ENABLED
- 错误转储输出下也会显示刀片式服务器故障事件
2022/05/09-18:16:38, [BL-1006], 389, SLOT 1 | FID 128, INFO, switch_name, Blade 8 NOT faulted. Peer blade 4 experienced abrupt failure.
2022/05/09-18:16:38, [BL-1006], 390, SLOT 1 | FID 128, INFO, switch_name, Blade 8 NOT faulted. Peer blade 4 experienced abrupt failure.
2022/05/09-18:16:40, [EM-1134], 391, SLOT 1 | FFDC | CHASSIS, ERROR, switch_name, Slot 4 set to faulty, rc=2005a.
2022/05/09-18:16:40, [EM-1069], 392, SLOT 1 | CHASSIS, INFO, switch_name, Slot 4 is being powered off.
2022/05/09-18:16:41, [EM-1134], 393, SLOT 1 | FFDC | CHASSIS, ERROR, switch_name, Slot 7 set to faulty, rc=20015.
2022/05/09-18:17:01, [MAPS-1021], 396, SLOT 1 | FID 128, WARNING, switch_name, RuleName=defCHASSISFAULTY_BLADE_1, Condition=CHASSIS(FAULTY_BLADE>=1), Obj:Chassis [ FAULTY_BLADE,2] has contributed to switch status MARGINAL.
2022/05/09-18:17:01, [MAPS-1021], 397, SLOT 1 | FID 128, WARNING, switch_name, RuleName=defCHASSISDOWN_CORE_1, Condition=CHASSIS(DOWN_CORE>=1), Obj:Chassis [ DOWN_CORE,1] has contributed to switch status MARGINAL.
2022/05/09-18:17:01, [MAPS-1020], 398, SLOT 1 | FID 128, WARNING, switch_name, Switch wide status has changed from HEALTHY to MARGINAL.
由于这些刀片式服务器错误、交换机状态将从运行状况变为边际状态。