FOS升级后、Brocade交换机上的响应速度较慢
适用场景
- Brocade 交换机
- FOS 8.3.2b
- 光纤连接 MetroCluster
问题描述
- Brocade交换机升级 到FOS 8.3.2b
- 升级后、 从交换机执行命令间歇性地需要很长时间才能显示 输出:
[root@XXXX 1234]# time ssh admin@user 'switchshow'
 admin@user's password:
 switchName:    Brocade-sw1
 switchType:    118.1
 switchState:   Online
 switchMode:    Native
 switchRole:    Principal
 switchDomain:   8
 switchId:     fffc08
 switchWwn:    10:00:XX:XX:XX:XX:XX:a0
 zoning:      ON (XX)
 switchBeacon:   OFF
 HIF Mode:     OFF
Index Port Address  Media Speed   State     Proto
 ==================================================
   0   0   080000   id   16G    Online    FC  F-Port  50:0a:09:81:0b:17:46:60
   1   1   080100   id   16G    No_Light   FC  (POD license not assigned or reserved yet)
 
   ---//Command output shortened//---
 
   22  22   081600   --   16G    No_Module   FC  LE (POD license not assigned or reserved yet)
   23  23   081700   --   16G    No_Module   FC  LE (POD license not assigned or reserved yet)
real   2m13.168s
 user   0m0.015s
 sys    0m0.016s
- 此缺陷的现象是SNMP守护进程上报告的CPU使用率较高。