由于缆线或SFP出现故障、在Rx电源低的Brocade交换机端口上报告PCS错误
适用场景
Brocade 交换机
问题描述
- 在交换机端口上观察到PCS错误:
/fabos/cliexec/porterrshow : frames enc crc crc too too bad enc disc link loss loss c3timeout pcs uncor tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err 172: 276 165 0 3 2 0 0 1 0 0 2 0 2 0 0 89.7m 0
- 报告RX低功率:
=============
Slot 5/Port 28:
=============
RX Power: -6.9 dBm (203.9uW)
TX Power: -1.1 dBm (784.2 uW)
portstatsshow
输出报告er_pcs_blk
错误计数器、如下所示:
portstatsshow 135 er_bad_os 0 Invalid ordered set er_pcs_blk 510 PCS block errors
规则-
defALL_HOST_PORTSITW_21
或defALL_32GSWL_SFPRXP_63
在errdump下触发:
2022/10/19-03:45:31, [MAPS-1003], 257687, SLOT 2 | FID 128, WARNING, XXX, slot12 port13, F-Port 12/13, Condition=ALL_HOST_PORTS(ITW/min>21), Current Value:[ITW, 20777 ITWs], RuleName=defALL_HOST_PORTSITW_21, Dashboard Category=Port Health.
2022/10/19-03:46:25, [MAPS-1004], 257747, SLOT 2 | FID 128, INFO, XXX, SFP 12/13, Condition=ALL_32GSWL_SFP(RXP<=63), Current Value:[RXP, 44 uW], RuleName=defALL_32GSWL_SFPRXP_63, Dashboard Category=Port Health.
- 检查sfpshow下交换机端的Rx电源,并确保Rx 电源 在 建议范围内。
- Low Rx power (低Rx电源)指示并问题描述上游到 交换机、请参阅Brocade交换机上报告的Low Rx power (低Rx电源)、原因是终端设备出现故障
- 或者、您也可以 按照以下步骤插入已知正常的设备、以便对缆线和SFP进行故障隔离:
- 为了对硬件进行故障隔离、请将缆线移至交换机端的下一个可用端口、并观察是否有任何增量:
- 如果新端口出现问题、请更换电缆/配线板并验证端口计数器
- 如果问题描述未连接到新端口、请将受影响端口的SFP交换为已知正常工作的SFP、并查看错误是否已解决
- 清除交换机统计信息(
statsclear
和slotstatsclear
),并观察端口(使用porterrshow
)以进一步验证是否仍记录了错误。