跳转到主内容

Brocade交换机上记录了"IT_FLOW "事件

Views:
41
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

Brocade 交换机上的端口

问题描述

  • IT-FLOW ” 事件记录在 Brocade交换机上的errdump 下:

2023/06/18-00:00:16:536399 (IST), [MAPS-2938], 862272/753764, SLOT 2 | FID 128, WARNING, BROCADESW, Pid 0x6fc5xx, Condition=ALL_LOCAL_PIDS(IT_FLOW/NONE>16), Current Value:[IT_FLOW, 37 IT-Flow(s)], RuleName=defALL_LOCAL_PIDSIT_FLOW_16, Dashboard Category=Fabric Performance Impact, Quiet Time=None., raslogAction.c, line: 218, comp:md, ltime:2023/06/18-00:00:16:536221
2023/06/18-00:00:16:537623 (IST), [MAPS-2938], 862273/753765, SLOT 2 | FID 128, WARNING, BROCADESW, Pid 0x6f7dxx, Condition=ALL_LOCAL_PIDS(IT_FLOW/NONE>16), Current Value:[IT_FLOW, 47 IT-Flow(s)], RuleName=defALL_LOCAL_PIDSIT_FLOW_16, Dashboard Category=Fabric Performance Impact, Quiet Time=None., raslogAction.c, line: 218, comp:md, ltime:2023/06/18-00:00:16:537440

  • defIT_RES_USAGE_P_75 映射警报已触发:

maps_alerts.png

  • mapsdb --show 输出中,我们可以看到dflt_moderate_policyActive策略

1 Dashboard Information:
=======================
DB start time:   Mon May 15 22:10:32 2023
Active policy:   dflt_moderate_policy 
Configured Notifications: RASLOG,SNMP,SW_CRITICAL,SW_MARGINAL,SFP_MARGINAL,SDDQ,UNQUAR,RE_BALANCE
Fenced Ports :   None
Decommissioned Ports :  None
Fenced circuits :  None
Quarantined Ports :  None
Top Zoned PIDs <pid(it-flows)>: 0x6f6dxx(60) 0x6f6cxx(60) 0x6fcbxy(60) 0x6f2dxy(60) 0x6fcbyy(60)

  • 在上述mapsdb --show 输出中、它还会显示具有最高IT_flow比率的PID/终端设备。  这些信息也会显示在errdump 下的错误日志中。

2023/06/18-00:00:16:537623 (IST), [MAPS-2938], 862273/753765, SLOT 2 | FID 128, WARNING, BROCADESW, Pid 0x6fcbyy, Condition=ALL_LOCAL_PIDS(IT_FLOW/NONE>16), Current Value:[IT_FLOW, 47 IT-Flow(s)], RuleName=defALL_LOCAL_PIDSIT_FLOW_16, Dashboard Category=Fabric Performance Impact, Quiet Time=None., raslogAction.c, line: 218, comp:md, ltime:2023/06/18-00:00:16:537440

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.