brocade<a>2009年381337</a><a>翻译</a>
Last Updated:

适用场景

  • Brocade互联阵列
  • HPE互连

问题描述

  • 连接到Brocade交换机的HPE互连端口/上行链路已关闭
  • 在服务器和交换机之间使用4根SFP分支缆线连接QSFP
  • 在Brocade交换机上,所有4个互连端口都处于 Disabled 下的状态 switchshow
 /fabos/bin/switchshow: switchName: SWXXXX switchType: 118.1 switchState: Online Index Port Address Media Speed State Proto ================================================== 8 8 010800 id N16 No_Sync FC Disabled (Port Throttled) 9 9 010900 id N16 No_Sync FC Disabled (Port Throttled) 10 10 010a00 id N16 No_Sync FC Disabled (Port Throttled) 11 11 010b00 id N16 No_Sync FC Disabled (Port Throttled)
  • Porterrshow 报告 Loss of signal 互连端口上的错误。
 /fabos/cliexec/porterrshow: frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor 8: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 9: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 10: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 11: 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.