跳转到主内容

对Brocade交换机端口进行连续链路重置(LR)

Views:
369
Visibility:
Public
Votes:
6
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

  • 所有Brocade FC交换机平台
  • 所有Brocade光纤操作系统固件级别

问题描述

  • 报告一个端口上的链路重置:

2020/09/01-09:22:48 (CET), [C5-1014], 2001, CHASSIS | PORT 0/13, WARNING, BrocadeG720,  Link Reset on Port S0,P13(52) vc_no=0 crd(s)lost=5 auto trigger.

  • 端口#上的映射报告连续链路重置(LR),如errdump -a 中所示:
2020/09/01-14:54:34, [MAPS-1003], 796, FID 128, WARNING, brocade_switch, onpom_fc0, F-Port 13, Condition=ALL_F_PORTS(LR/min>=1), Current Value:[LR, 2], RuleName=CNLV_CMPLNT_LR, Dashboard Category=Port Health.
2020/09/01-15:16:53, [LOG-1000], 798, FID 128, INFO, brocade_switch, Previous message repeated 2 time(s).
2020/09/01-15:20:34, [MAPS-1003], 799, FID 128, WARNING, brocade_switch, onpom_fc0, F-Port 13, Condition=ALL_F_PORTS(LR/min>=1), Current Value:[LR, 2], RuleName=CNLV_CMPLNT_LR, Dashboard Category=Port Health.
2020/09/01-15:46:53, [LOG-1000], 802, FID 128, INFO, brocade_switch, Previous message repeated 3 time(s).
2020/09/01-15:46:58, [MAPS-1003], 803, FID 128, WARNING, brocade_switch, onpom_fc0, F-Port 13, Condition=ALL_F_PORTS(LR/min>=1), Current Value:[LR, 4], RuleName=CNLV_CMPLNT_LR, Dashboard Category=Port Health.
2020/09/01-15:56:10, [MAPS-1003], 804, FID 128, WARNING, brocade_switch, onpom_fc0, F-Port 13, Condition=ALL_F_PORTS(LR/min>=1), Current Value:[LR, 2], RuleName=CNLV_CMPLNT_LR, Dashboard Category=Port Health.
2020/09/01-16:01:22, [MAPS-1003], 805, FID 128, WARNING, brocade_switch, onpom_fc0, F-Port 13, Condition=ALL_F_PORTS(LR/min>=1), Current Value:[LR, 4], RuleName=CNLV_CMPLNT_LR, Dashboard Category=Port Health.
2020/09/01-16:16:53, [LOG-1000], 806, FID 128, INFO, brocade_switch, Previous message repeated 1 time(s).
2020/09/01-16:23:40, [MAPS-1003], 807, FID 128, WARNING, brocade_switch, onpom_fc0, F-Port 13, Condition=ALL_F_PORTS(LR/min>=1), Current Value:[LR, 4], RuleName=CNLV_CMPLNT_LR, Dashboard Category=Port Health.
 
  • 验证porterrshow会报告过多的链路故障计数器:

      frames    enc   crc   crc   too   too   bad   enc   disc   link   loss   loss   frjt   fbsy  c3timeout   pcs   uncor
    tx    rx    in   err   g_eof  shrt   long   eof    out   c3   fail   sync   sig          tx   rx    err   err
376:  298.7k 501.9k   0    0    0    0    0    0    0    0    9.9k   0    0    0    0    0    0    0    0

  • 中断、lli、proc_Rqrd、LR_IN、LR_OUT、OLS_IN、OLS_OUT在portshow 中增加:

portshow 13
portDisableReason: None
portCFlags: 0x1
portFlags: 0x24b03    PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE LOGIN NOELP LED ACCEPT FLOGI
LocalSwcFlags: 0x0
portType:  26.0
POD Port: Port is licensed
portState: 1   Online   
Protocol: FC
portPhys:  6   In_Sync     portScn:   32   F_Port   
port generation number:   93268
state transition count:   92939    

portId:   0a0d00
portIfId:   43020034
portWwn:   20:0d:88:94:71:b1:69:c0
portWwn of device(s) connected:
   21:00:00:24:ff:1d:8c:e2
16b Area list:
Distance:  normal
portSpeed: N16Gbps

FEC: Inactive
Credit Recovery: Inactive
Aoq: Inactive
FAA: Inactive
F_Trunk: Inactive
LE domain: 0
Peer beacon: Off
FC Fastwrite: OFF
Interrupts:     9909    Link_failure: 3      Frjt:      0      
Unknown:       0      Loss_of_sync: 0      Fbsy:      0      
Lli:         9909    Loss_of_sig:  0      
Proc_rqrd:      211621   Protocol_err: 0      
Timed_out:      0      Invalid_word: 0      
Tx_unavail:     0      Invalid_crc:  0      
Delim_err:      0      Address_err:  0      
Lr_in:        4914    Ols_in:     4877    
Lr_out:       4877    Ols_out:    4914 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.