跳转到主内容

由于硬件问题、C3 Tx丢弃和帧超时

Views:
215
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

 

适用场景

Brocade Fabric OS 

问题描述

  • errdump -a 记录帧超时、指出哪个端口接收到帧(Rx)以及无法在何处 (TX)传输帧、同时记录丢失信号和超额预订警报。

2022/02/09-22:31:04, [AN-1014], 2266, SLOT 2 | FID 128, INFO, NFAB1, Frame timeout detected, tx port 9/7 rx port 9/27, sid c8f907, did 678740, timestamp 2022-02-09 22:31:04 .
2023/12/23-10:47:16 (IST), [MAPS-1003], 274485, SLOT 2 | FID 128 | PORT 11/8, WARNING, switch, IB_INFINI_3185_W_N3P6, F-Port 11/8, Condition=ALL_PORTS(PORT_BANDWIDTH/NONE==OVERSUBSCRIBED), Current Value:[PORT_BANDWIDTH, OVERSUBSCRIBED, (TXQL=914 us, TX=72.8%) ], RuleName=defALL_PORTS_OVERSUBSCRIBED, Dashboard Category=Fabric Performance Impact, Quiet Time=15 min.
2023/12/18-01:35:43 (IST), [MAPS-1003], 270764, SLOT 1 | FID 128 | PORT 10/21, WARNING, switch, Nimble2_U_N2S3P1, U-Port 10/21, Condition=ALL_PORTS(LOSS_SIGNAL/min>5), Current Value:[LOSS_SIGNAL, 8 LOS], RuleName=defALL_PORTSLOSS_SIGNAL_5, Dashboard Category=Port Health, Quiet Time=None.

 

  • Frame loss 中记录的事件在交换机端的errdump-

2024/12/02-04:56:04 (IST), [MAPS-1001], 1664654, SLOT 2 | FID 128 | PORT 12/8, CRITICAL, switch, slot12 port8, F-Port 12/8, Condition=ALL_PORTS(DEV_LATENCY_IMPACT/NONE==IO_FRAME_LOSS), Current Value:[DEV_LATENCY_IMPACT, IO_FRAME_LOSS, (174 ms Frame Delay in VC: 2) ], RuleName=ALL_PORTS_IO_FRAME_LOSS_UNQUAR, Dashboard Category=Fabric Performance Impact, Quiet Time=1 day.

 

  • porterrshow 显示link failureslink resetsc3 discards tx frame timeouts 相关的错误计数器增量。

/fabos/cliexec/porterrshow:
      frames     enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy   c3timeout   pcs    uncor
     tx     rx    in    err    g_eof   shrt   long   eof    out   c3   fail   sync   sig            tx   rx    err    err
391:   45.3g   3.4g   0     0     0     0     0     0     0    43.1k   5     0     5     0     0    43.1k   0     0     2.5k

 

  • sfpshow 表示接收功率低

=============
Port  391:
=============
RX Power:    -8.1    dBm (155.8uW)
TX Power:    -3.0    dBm (500.6 uW)

 

  • portshow 表示远程设备重置 链路的次数超过本地端口发送的脱机原值

portshow 391
[...]
Lr_in:             133     Ols_in:       5
Lr_out:            7       Ols_out:      6

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.