跳转到主内容

Brocade交换机端口会被自动禁用

Views:
94
Visibility:
Public
Votes:
1
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

 

 

适用场景

  • 所有Brocade交换机硬件平台
  • 所有Brocade Fabric Operating System (FOS)固件级别

问题描述

  • 发生故障的Brocade交换机端口交换机会禁用此端口以防止发生闪烁
  • 在switchshow下、端口状态显示为"No_sync"或 "No_Module "

示例:

errdump -a

WARNING, Brocade Fabric 1, Port 4 Faulted because of many Link Failures.
 
2022/03/17-21:47:29, [MAPS-2030], 1507, SLOT 1 | FID 128, WARNING, NETAPP_FAB1, slot6 port4, F-Port 6/4, Condition=ALL_TARGET_PORTS(STATE_CHG/min>3), Current Value:[STATE_CHG, 4], RuleName=defALL_TARGET_PORTSSTATE_CHG_3, Dashboard Category=Port Health. 2022/03/17-21:47:41, [MAPS-2030], 1508, SLOT 1 | FID 128, WARNING, NETAPP_FAB1, slot6 port4, F-Port 6/4, Condition=ALL_OTHER_F_PORTS(STATE_CHG/min>5), Current Value:[STATE_CHG, 6], RuleName=defALL_OTHER_F_PORTSSTATE_CHG_5, Dashboard Category=Port Health. 2022/03/23-14:25:14, [MAPS-2030], 1571, SLOT 1 | FID 128, WARNING, NETAPP_FAB1, slot6 port4, F-Port 6/4, Condition=ALL_TARGET_PORTS(STATE_CHG/min>3), Current Value:[STATE_CHG, 4], RuleName=defALL_TARGET_PORTSSTATE_CHG_3, Dashboard Category=Port Health. 2022/03/23-15:42:50, [MAPS-2030], 1581, SLOT 1 | FID 128, WARNING, NETAPP_FAB1, slot6 port4, F-Port 6/4, Condition=ALL_TARGET_PORTS(STATE_CHG/min>3), Current Value:[STATE_CHG, 4], RuleName=defALL_TARGET_PORTSSTATE_CHG_3, Dashboard Category=Port Health.
 
switchshow

64  4   4   150400   --   N32    No_Module  FC  Disabled

140 3 28 668c40 id N32 NO_Sync FC已禁用

  • sfpshow 指示Tx极低、低于建议值

sfpshow -all

RX Power:    -2.1    dBm (623.1uW)
TX Power:    -6.2    dBm (237.3 uW)

  • sfpshow 指示器Rx和Tx处于最佳范围

RX Power:   -1.9   dBm (652.9uW) 
TX Power:   -0.3   dBm (939.5 uW)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.