问题描述

  •  No_light  switchshow 对于F端口 或ISL端口、输出下方会显示交换机端口:

Index Port Address Media Speed  State    Proto
==============================================
   5   5   0xx500   id     4G   No_Light    FC Disabled  

  • porterrshow 表示链路故障和丢失SIG错误

/fabos/cliexec/porterrshow :
      frames     enc    crc    crc    too    too    bad    enc   disc   link  loss   loss  frjt   fbsy    c3timeout    pcs    uncor
     tx     rx    in    err    g_eof   shrt   long   eof    out   c3    fail  sync   sig           tx    rx    err    err
  65:   5.4g   9.4g   0     0     0     0     0     0     0     0    1    0    1    0     0     0     0     0     0

  • Portshow 受影响的端口报告 offline 状态:

portshow 5
portDisableReason: None
portCFlags: 0x0
portFlags: 0x21    PRESENT U_PORT DISABLED
LocalSwcFlags: 0x0
portType:  26.0
portState: 2   Offline  
Protocol: FC
portPhys:  4   No_Light    portScn:   2   Offline   
port generation number:   748
state transition count:   11    

  • sfpshow 将 Rx stat报告为-inf.

Slot  3/Port 42:
=============
Identifier:  3   SFP
Connector:   7   LC
[...]
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000333-01
Vendor Rev:  A
[...]
Temperature: 53    Centigrade
Current:    7.496   mAmps
Voltage:    3312.0  mVolts
RX Power:   -inf   dBm (0.0  uW)
TX Power:   -0.3   dBm (924.1 uW)

  • sfpshow 将Tx统计报告为-inf.

Slot  9/Port  1:
=============
Identifier:  3   SFP
Connector:   7   LC
[...]
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000333-01
Vendor Rev:  A
[..]
Temperature: 43    Centigrade
Current:    0.000   mAmps
Voltage:    3313.0  mVolts
RX Power:   -0.6   dBm (880.7uW)
TX Power:   -inf   dBm (0.0   uW)

  • fabriclog 表示端口已转接并脱机

Switch 0; Wed Aug 16 12:15:31 2023 GMT (GMT+0:00)
12:15:31.681477 SCN LR_PORT(0);g=0x0             D2,P0  D2,P0  27   NA   
12:15:31.695830 SCN Port Online; g=0x0,isolated=0       D2,P0  D2,P1  27   NA   
12:15:31.696439 Port Elp engaged               D2,P1  D2,P0  27   NA   
12:15:31.696468 *Removing all nodes from port         D2,P0  D2,P0  27   NA   
12:15:31.696612 SCN Port F_PORT                D2,P1  D2,P0  27   NA   
12:15:53.257221 SCN Port Offline;rsn=0x1,g=0x4a        D2,P0  D2,P0  27   NA   
12:15:53.257228 *Removing all nodes from port         D2,P0  D2,P0  27   NA   

  • 两个交换机上的ISL端口均出现闪烁。
  • 对于ISL端口终端设备交换机、可以验证Rx和Tx值以进行故障隔离。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.