Brocade交换机端口处于脱机状态、LS已禁用(锁定为E端口)
适用场景
Brocade 交换机上的端口
问题描述
- Brocade FC端口处于No_Sync状态、并 根据
switchshow
输出禁用LS
Index Slot Port Address Media Speed State Proto
============================================================
262 3 38 668ec0 id 16G No_Sync FC LS Disabled (Locked as E-port)
porterrorshow
不报告端口上的错误。
/fabos/cliexec/porterrshow :
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
262: 5 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
sfpshow
将Tx stat报告为-INF和低Rx功率。
Slot 3/Port 38:
=============
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 6801001200000000 8,16,32_Gbps SM lw Extended Long_dist
[...........]
Vendor Name: BROCADE
Vendor OUI: 00:05:1e
Vendor PN: 57-1000335-01
[...........]
Temperature: 60 Centigrade
Current: 0.000 mAmps
Voltage: 3318.0 mVolts
RX Power: -13.8 dBm (41.6 uW)
TX Power: -inf dBm (0.0 uW)
portshow
受影响的端口报告 锁定为E端口 状态:
portshow 262
portDisableReason: Locked as E-port
portCFlags: 0x0
portFlags: 0x4021 PRESENT U_PORT DISABLED LED
LocalSwcFlags: 0x0
portType: 26.0
portState: 2 Offline
Protocol: FC
portPhys: 5 No_Sync portScn: 2 Offline
port generation number: 0
state transition count: 1