由于交换机端SFP出现故障、Brocade交换机处于IN _ SYNC状态
适用场景
- ONTAP 9
- Brocade 交换机上的端口
- SAN
问题描述
- 交换机端口状态
In_Sync
在switchshow输出下显示 :
Index Port Address Media Speed State Proto
==================================================
xx xx 052b00 id N16 In_Sync FC
porterrshow
输出显示出现链路故障错误:
/fabos/csiexec/porterrshow:
Frame enc CRC Too bad enc Disc link Loss frjt fbsyc3timeout pcs uncorr TX Rx in errg_eof srt long eof out C3 fail
sync sig tx Rx errr 错误
xx: 0 0 0 0 0 0 0 0 0 0 0 11.3k 0 11.2000 0 0 0 0 0 0
- 交换机SFP似乎工作正常:
RX Power: -2.6 dBm (547.9uW)
TX Power: -0.8 dBm (832.1 uW)
sysconfig -a
在ONTAP上、连接的交换机端口状态显示为未知:
slot 2: Fibre Channel Target Host Adapter XX
(QLogic 8324 (8362) rev. 2, <LINK NOT CONNECTED>)
Board Name: QLE2672
Serial Number: RFE1XXX2946
Firmware rev: 8.9.0
Flash rev: 1.1.2
Host Port Addr: 000000
FC Nodename: 50:0a:09:80:x0:xx:fc:d0 (500a098xxxxxxfcd0)
FC Portname: 50:0a:09:83:80:b1:fc:xx (500a09xxx80b1fcd0)
Connection: No link
Switch Port: Unknown
SFP Vendor Name: FINISAR CORP.
SFP Vendor P/N: FTLF8529P3BCV-EM
SFP Vendor Rev: B
SFP Serial No.: PY306G1
SFP Connector: LC
- 更换缆线没有帮助。
- 更换交换机SFP没有任何帮助。