启动后、Brocade X7-8多端口刀片式服务器出现故障
适用场景
- Brocade X7-8
- FC64-48端口刀片
- Brocade Fabric OS (FOS)
问题描述
- 新导向器中
FAULTY (21)的两个交换机刀片在中显示slotshow:
Slot Blade Type ID Status----------------------------------- 1 CP BLADE 220 ENABLED 2 CP BLADE 220 ENABLED 3 SW BLADE 216 ENABLED 4 SW BLADE 216 FAULTY (21) 5 SW BLADE 216 FAULTY (21) 6 SW BLADE 216 ENABLED 7 CORE BLADE 215 ENABLED 8 CORE BLADE 215 ENABLED 9 SW BLADE 216 ENABLED 10 SW BLADE 216 ENABLED 11 UNKNOWN VACANT 12 UNKNOWN VACANT- 重新拔插一个或两个刀片式服务器不会将端口刀片式服务器启动为
ENABLED。 - 例如,根据控制台输出或,插槽4首先出现故障,插槽5随后出现故障
errdump:
11:50:23, [BL-1002], 5394, SLOT 2 | FFDC | CHASSIS, CRITICAL, switch, Init Failed: slot 4 DISABLED because internal ports were not ONLINE, ports: 41 42 43 44 45 46 105 106 107 108 109 110 .11:50:23, [EM-1134], 5395, SLOT 2 | FFDC | CHASSIS, ERROR, switch, Slot 4 set to faulty, rc=20015.11:54:38, [BL-1002], 5407, SLOT 2 | FFDC | CHASSIS, CRITICAL, switch, Init Failed: slot 5 DISABLED because internal ports were not ONLINE, ports: 110 .11:54:38, [EM-1134], 5408, SLOT 2 | FFDC | CHASSIS, ERROR, switch, Slot 5 set to faulty, rc=20015.