跳转到主内容

Brocade X6-8导向器在断电后无法联机

Views:
1
Visibility:
Internal
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade<a>2009818586</a>
Last Updated:

适用场景

  • FC
  • SAN
  • Brocade x6-8
  • Brocade Fabric OS ( FOS )

问题描述

  • 交换机脱机/禁用:

switchshow     :
switchName:    switch
switchType:    166.0
switchState:   Offline
switchMode:    Native
switchRole:    Disabled

  • 两个核心刀片都正在 启动或显示为故障、其他刀片也可能已关闭:
slotshow -m    :
 
Slot  Blade Type   ID   Model Name   Status
--------------------------------------------------
  1   CP BLADE   175   CPX6      ENABLED
  2   CP BLADE   175   CPX6      ENABLED
  3   UNKNOWN               VACANT
  4   SW BLADE   178   FC32-48     INSERTED, NOT POWERED ON
  5   SW BLADE   178   FC32-48     INSERTED, NOT POWERED ON
  6   SW BLADE   178   FC32-48     ENABLED
  7   CORE BLADE  177   CR32-8     FAULTY (21)
  8   CORE BLADE  177   CR32-8     DIAG RUNNING POST2
  9   SW BLADE   178   FC32-48     ENABLED
10   SW BLADE   178   FC32-48     ENABLED
11   UNKNOWN               VACANT
12   UNKNOWN               VACANT
  • 重新安装单个刀片式服务器或同时重新安装两个核心刀片式服务器不会使刀片式服务器恢复工作。
  • 使用 slotPowerOff 和重新启动刀片式服务器 slotPowerOn 不会使刀片式服务器恢复运行。
  • 重新启动交换机不会重新启动刀片式服务器。
  • 日志显示插槽7和8中的两个核心刀片式服务器无法启动:
2023/11/02-11:15:32, [BL-1017], 1157, SLOT 2 | CHASSIS, INFO, X6-8, Slot 7 Initializing...
2023/11/02-11:15:52, [BL-1019], 1158, SLOT 2 | CHASSIS, INFO, X6-8, Slot 7, retry 1, internal port retry initialization, ports: 220 .
2023/11/02-11:16:02, [BL-1019], 1159, SLOT 2 | CHASSIS, INFO, X6-8, Slot 7, retry 2, internal port retry initialization, ports: 217 220 .
2023/11/02-11:16:12, [BL-1002], 1160, SLOT 2 | FFDC | CHASSIS, CRITICAL, X6-8, Init Failed: slot 7 DISABLED because internal ports were not ONLINE, ports: 217 220 .
2023/11/02-11:16:12, [RAS-1002], 1161, SLOT 2 | CHASSIS, WARNING, X6-8, First failure data capture (FFDC) reached maximum storage size (15 MB).
2023/11/02-11:16:13, [EM-1134], 1162, SLOT 2 | FFDC | CHASSIS, ERROR, X6-8, Slot 7 set to faulty, rc=20015.
2023/11/02-11:21:54, [EM-2003], 1165, SLOT 2 | CHASSIS, ERROR, X6-8, Slot 8 has failed the POST tests. FRU is being faulted.
2023/11/02-11:21:54, [EM-1072], 1166, SLOT 2 | FFDC | CHASSIS, CRITICAL, X6-8, Chassis cannot become ready since no Core Blades are available.
  • 交换机自动重新启动并报告尚未就绪:
2023/11/02-11:29:37, [SWCH-1001], 1187, SLOT 2 | FID 128, ERROR, switch, Switch is not in ready state - Switch enable failed, switch status= 0x4, c_flags = 0x10400.
2023/11/02-11:35:39, [HAM-1007], 1188, SLOT 2 | FFDC | CHASSIS, CRITICAL, X6-8, Need to reboot the system for recovery, reason: Software Bootup Failure:Bringup timed out.
2023/11/02-11:36:09, [HAM-1008], 1189, SLOT 2 | FFDC | CHASSIS, CRITICAL, X6-8, Rebooting the system for recovery - auto-reboot is enabled.
  • hadump 显示CP刀片式服务器未同步:
Local CP (Slot 2, CP1): Active, Cold Recovered
Remote CP (Slot 1, CP0): Standby, Healthy
HA enabled, Heartbeat Up, HA State not in sync