Brocade G620风扇出现故障并恢复
适用场景
- Brocade G620
- Fabric OS (FOS) v9.1.1a
问题描述
- 风扇出现故障:
2024/06/14-01:41:42 (UTC), [HIL-1206], 58756, CHASSIS, ERROR, BrocadeG620, Fan 2 sensor 1 , speed (2649 RPM) below threshold.2024/06/14-01:41:42 (UTC), [MAPS-1002], 58757, FID 128, ERROR, ssw001, Fan 2, Condition=ALL_FAN(FAN_STATE/NONE==FAULTY), Current Value:[FAN_STATE, FAULTY], RuleName=defALL_FANFAN_STATE_FAULTY, Dashboard Category=Fru Health, Quiet Time=None.2024/06/14-01:41:42 (UTC), [EM-1034], 58758, CHASSIS, ERROR, BrocadeG620, Fan 2 set to faulty, rc=20006.2024/06/14-01:41:46 (UTC), [HIL-1301], 58761, CHASSIS, WARNING, BrocadeG620, 1 blower failed or missing. Replace failed or missing blower assembly immediately.- 恢复时间:
2024/06/14-01:41:50 (UTC), [MAPS-1003], 58762, FID 128, WARNING, ssw001, Fan 2, Condition=ALL_FAN(FAN_STATE/NONE==ON), Current Value:[FAN_STATE, ON], RuleName=defALL_FANFAN_STATE_ON, Dashboard Category=Fru Health, Quiet Time=None.- 风扇保持打开:
/fabos/cliexec/fanshow:Fan 1 is Ok, speed is 8341 RPMFan 2 is Ok, speed is 8239 RPM/fabos/cliexec/chassisshow:Chassis State: EnabledFAN Unit: 1Fan Direction: Non-portside IntakeTime Awake: 519 daysFAN Unit: 2Fan Direction: Non-portside IntakeTime Awake: 33 days- 电源和风扇部件状态指示灯呈稳定绿色