跳转到主内容

无法访问Brocade G610交换机

Views:
35
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade<a>2009560934</a>
Last Updated:

适用场景

  • Brocade G610交换机
  • Brocade G620交换机

问题描述

  • 交换机无响应、无法访问交换机电源正常
  • SSH和WebGUI无法正常工作
  • Ping交换机管理IP无应答
  • 重新加电 开关不变
  • 已换用确认工作正常的电源线、但情况没有变化
  • 已将交换机的电源线连接到其他电源
  • 已连接 交换机串行端口 缆线无登录提示、仅启动菜单或 安全启动模式

=> help
Unsupported command 'help' in Secure Boot Mode
=> ?
Unsupported command '?' in Secure Boot Mode

 

  • 重新启动交换机、仍然不显示登录提示、但会显示以下错误消息。

SerialNumber B8F0022700977077
 - Vendor: 0x0634  Product 0x1270 Version 17.18
2 USB Device(s) found
    scanning usb for storage devices... 1 Storage Device(s) found
setting prt to 2
Secure Boot Mode Enabled, System in Trusted State
Hit ESC to stop autoboot:  0
** File not found /boot/signed_bzImage.itb **
2805 bytes read in 430 ms (5.9 KiB/s)
## Executing script at 00200000
sha1,rsa2048:dev+ sha1+ WARNING: adjusting available memory to 30000000
Wrong Image Format for bootm command
ERROR: can't get kernel image!

  • 故障排除后、可能会发现未找到文件

Secure Boot Mode Enabled, System in Trusted State
Hit ESC to stop autoboot:  0
** File not found /boot/signed_bzImage.itb **
** File not found /boot/signed_inithash.itb **
Wrong image format for "source" command

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.