适用场景

Brocade FabricOS (FOS) 

问题描述

  • SANNAV FOS升级显示超时消息:

SWITCH:admin> firmwaredownloadstatus

[1]: Sat Sep 14 23:36:11 2024
Slot 1 (CP0, active): Firmware is being downloaded to standby CP. This step may take up to 30 minutes.

[2]: Sun Sep 15 00:06:11 2024
Slot 1 (CP0, active): Firmware download failed on standby CP - Firmware download timed out. (0x23)

[3]: Sun Sep 15 00:06:20 2024
Slot 1 (CP0, active): Please use firmwaredownloadstatus and firmwareshow to see the firmware status.

  • 交换机似乎正忙于处理 有关流量影响的多个映射警报:

2023/04/10-22:10:36:223765 (IST), [MAPS-1005], 428700/228252, SLOT 2 | FID 128, WARNING, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=5/14), Condition=sys_flow_monitor_scsi(RD_1stDATA_TIME/10SEC>11000), Current Value:[RD_1stDATA_TIME, 11239 Microseconds], Rule defRD_1stDATA_TIME_11000 triggered 2 times in 10 min and last trigger time Mon Apr 10 22:07:37 2023, Dashboard Category=IO Latency., raslogAction.c, line: 233, comp:md, ltime:2023/04/10-22:10:36:223568

2023/04/10-22:10:36:224539 (IST), [MAPS-1006], 428701/228253, SLOT 2 | FID 128, INFO, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=5/14), Latest Value=[RD_1stDATA_TIME, 11239 Microseconds]., raslogAction.c, line: 244, comp:md, ltime:2023/04/10-22:10:36:223703

2023/04/10-22:11:36:225540 (IST), [MAPS-1005], 428702/228254, SLOT 2 | FID 128, WARNING, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=12/10), Condition=sys_flow_monitor_scsi(RD_1stDATA_TIME/10SEC>11000), Current Value:[RD_1stDATA_TIME, 15935 Microseconds], Rule defRD_1stDATA_TIME_11000 triggered 2 times in 10 min and last trigger time Mon Apr 10 22:01:17 2023, Dashboard Category=IO Latency., raslogAction.c, line: 233, comp:md, ltime:2023/04/10-22:11:36:225343

2023/04/10-22:11:36:226424 (IST), [MAPS-1006], 428703/228255, SLOT 2 | FID 128, INFO, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=12/10), Latest Value=[RD_1stDATA_TIME, 15935 Microseconds]., raslogAction.c, line: 244, comp:md, ltime:2023/04/10-22:11:36:225480

2023/04/10-22:11:36:226465 (IST), [MAPS-1005], 428704/228256, SLOT 2 | FID 128, WARNING, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=12/10), Condition=sys_flow_monitor_scsi(RD_STATUS_TIME/10SEC>12000), Current Value:[RD_STATUS_TIME, 15941 Microseconds], Rule defRD_STATUS_TIME_12000 triggered 2 times in 10 min and last trigger time Mon Apr 10 22:01:17 2023, Dashboard Category=IO Latency., raslogAction.c, line: 233, comp:md, ltime:2023/04/10-22:11:36:226109

2023/04/10-22:11:36:226499 (IST), [MAPS-1006], 428705/228257, SLOT 2 | FID 128, INFO, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=12/10), Latest Value=[RD_STATUS_TIME, 15941 Microseconds]., raslogAction.c, line: 244, comp:md, ltime:2023/04/10-22:11:36:226243

请参见: Fabric OS System Messages

  • 这些map事件可能会在发生原因下载代码并在内部复制代码时出现问题。
  • 检查在升级期间是否发现任何网络问题。

 

  • 可按以下步骤增加超时值-
    • 等待 firmwareDownload  操作完成(大约30分钟)。
    • 使用将超时时间增加到40分钟  firmwareDownload -x 2400
    • 如果 此操作未完成、请运行 firmwareDownload -s 命令将备用CP上的固件升级到与 活动CP相同的版本。然后重试firmwareDownload  命令、将所需的 固件版本下载到CPS。

 

  • 如果上述步骤无法解决问题描述问题、请继续执行解决方案中提到的其他步骤。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.