由于超时, Brocade Fabric OS 更新失败
适用场景
Brocade FabricOS (FOS)
问题描述
在 固件升级期间、firmwaredownloadstatus输出会显示以下条目:
set_status:CP1 Firmware download failed on standby CP - Firmware download timed out. (0x23)
交换机似乎正忙于处理 有关流量影响的多个映射警报:
2023/04/10-22:10:36:223765 (IST), [MAPS-1005], 428700/228252, SLOT 2 | FID 128, WARNING, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=5/14), Condition=sys_flow_monitor_scsi(RD_1stDATA_TIME/10SEC>11000), Current Value:[RD_1stDATA_TIME, 11239 Microseconds], Rule defRD_1stDATA_TIME_11000 triggered 2 times in 10 min and last trigger time Mon Apr 10 22:07:37 2023, Dashboard Category=IO Latency., raslogAction.c, line: 233, comp:md, ltime:2023/04/10-22:10:36:223568
2023/04/10-22:10:36:224539 (IST), [MAPS-1006], 428701/228253, SLOT 2 | FID 128, INFO, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=5/14), Latest Value=[RD_1stDATA_TIME, 11239 Microseconds]., raslogAction.c, line: 244, comp:md, ltime:2023/04/10-22:10:36:223703
2023/04/10-22:11:36:225540 (IST), [MAPS-1005], 428702/228254, SLOT 2 | FID 128, WARNING, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=12/10), Condition=sys_flow_monitor_scsi(RD_1stDATA_TIME/10SEC>11000), Current Value:[RD_1stDATA_TIME, 15935 Microseconds], Rule defRD_1stDATA_TIME_11000 triggered 2 times in 10 min and last trigger time Mon Apr 10 22:01:17 2023, Dashboard Category=IO Latency., raslogAction.c, line: 233, comp:md, ltime:2023/04/10-22:11:36:225343
2023/04/10-22:11:36:226424 (IST), [MAPS-1006], 428703/228255, SLOT 2 | FID 128, INFO, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=12/10), Latest Value=[RD_1stDATA_TIME, 15935 Microseconds]., raslogAction.c, line: 244, comp:md, ltime:2023/04/10-22:11:36:225480
2023/04/10-22:11:36:226465 (IST), [MAPS-1005], 428704/228256, SLOT 2 | FID 128, WARNING, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=12/10), Condition=sys_flow_monitor_scsi(RD_STATUS_TIME/10SEC>12000), Current Value:[RD_STATUS_TIME, 15941 Microseconds], Rule defRD_STATUS_TIME_12000 triggered 2 times in 10 min and last trigger time Mon Apr 10 22:01:17 2023, Dashboard Category=IO Latency., raslogAction.c, line: 233, comp:md, ltime:2023/04/10-22:11:36:226109
2023/04/10-22:11:36:226499 (IST), [MAPS-1006], 428705/228257, SLOT 2 | FID 128, INFO, Brocade, Flow (SID=0x6a2xx0,DID=0x66ayy0,Host Port=12/10), Latest Value=[RD_STATUS_TIME, 15941 Microseconds]., raslogAction.c, line: 244, comp:md, ltime:2023/04/10-22:11:36:226243
- 错误代码
0x23
会转换为错误消息:Firmware download timed out
根据 Brocade Fabric OS消息参考手册、9.1.X (页码:1231)
请参见: Fabric OS System Messages
- 这些map事件可能会在发生原因下载代码并在内部复制代码时出现问题。
- 检查在升级期间是否发现任何网络问题。