跳转到主内容

由于交换机SFP出现故障、Brocade FC端口脱机且NO_Sync状态

Views:
403
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

  • Brocade FC 交换机
  • 光纤操作系统(FOS) 

问题描述

  • 、Brocade FC端口处于根据switchshow 输出No_Syncdisabled 状态

/fabos/bin/switchshow :
Index Slot Port Address Media  Speed     State   Proto
============================================================
 106   11   10   676a40   id   N32  No_Sync   FC  Disabled

  • sfpshow 显示Tx值不在建议范围内

=============
Slot 11/Port 10:
=============
Transceiver: 6804404000000000 8,16,32_Gbps M5 sw Short_dist
Vendor PN:   57-1000333-01
RX Power:   -2.2   dBm (604.6uW)
TX Power:   -27.2   dBm (1.9   uW)

:已禁用端口且TX电源为-40表示激光已关闭,并不一定表示出现故障。

  • 启用此端口可确认TX电源始终小于300 UF

  • 根据switchshow 输出、Brocade FC端口处于No_Sync 状态

/fabos/bin/switchshow :
Index Slot Port Address Media  Speed     State   Proto
============================================================
127   12   15   107f40   id   N32     No_Sync   FC

  • Porterrshow 报告大量介质错误,包括pcs erroruncorr errorsc3 discards 以及link fail  和loss_sig 错误。

/fabos/cliexec/porterrshow :
      frames     enc    crc    crc    too    too    bad    enc   disc   link  loss  loss  frjt   fbsy    c3timeout   pcs   uncor
     tx     rx    in    err    g_eof   shrt   long   eof    out   c3    fail  sync  sig           tx    rx    err    err
  296:   12.4k   12.1k   0     0     0     0     0     0     0    11    1.5k   57.3k    9.2k  0     0    11     0   252   43.7k

 

  • portstatsshow 输出显示端口为offline & no_syn c state,禁用原因为port throttled

portshow 127
portDisableReason: Port Throttled
portCFlags: 0x0
portFlags: 0x61   PRESENT DISABLED
LocalSwcFlags: 0x0
portType:  26.0
portState: 2      Offline
Protocol: FC
portPhys:  5      No_Sync       portScn:   2      Offline

  • portstatsshow 输出显示端口为offline & no_syn c state

portshow 330
portDisableReason: None
portCFlags: 0x0
portFlags: 0x4021        PRESENT U_PORT DISABLED LED
LocalSwcFlags: 0x0
portType:  26.0
portState: 2      Offline
Protocol: FC
portPhys:  5      No_Sync       portScn:   2      Offline

  • Errdump 报告链路故障和丢失信号错误以及规则defNON_E_F_PORTSSTATE_CHG_20_FENCE  和ALL_SFP_32GSWL_TX_POWER_251 正在触发

2023/01/20-15:37:58, [MAPS-2022], 23317, SLOT 1 | FID 128, WARNING, SWITCHXX, slot6 port8 HBAXX_HBA1 DISABLED_LR_11112022, U-Port 6/8, Condition=ALL_PORTS(LOSS_SIGNAL/min>3), Current Value:[LOSS_SIGNAL, 70 LOS], RuleName=defALL_PORTSLOSS_SIGNAL_3, Dashboard Category=Port Health.
2023/01/20-15:38:28, [MAPS-2018], 23318, SLOT 1 | FID 128, WARNING, SWITCHXX, slot6 port8 HBAXX_HBA1 DISABLED_LR_11112022, U-Port 6/8, Condition=ALL_PORTS(LF/min>3), Current Value:[LF, 4 LFs], RuleName=defALL_PORTSLF_3, Dashboard Category=Port Health.
2023/03/06-17:48:07, [MAPS-1003], 89981, SLOT 1 | FID 128, WARNING, SWITCHXX, slot9 port15, U-Port 9/15, Condition=NON_E_F_PORTS(STATE_CHG/min>11), Current Value:[STATE_CHG, 14], RuleName=defNON_E_F_PORTSSTATE_CHG_11, Dashboard Category=Port Health.
2023/03/06-17:48:13, [MAPS-1010], 89983, SLOT 1 | FID 128, ERROR, SWITCHXX, Port(s) fenced due to RuleName=defNON_E_F_PORTSSTATE_CHG_20_FENCE, Condition=NON_E_F_PORTS(STATE_CHG/min>20), Obj:slot9 port15, U-Port 9/15 [ STATE_CHG,21]
2023/06/15-18:16:27, [MAPS-1005], 182673, SLOT 1 | FID 128, WARNING, H1NETxxx, SFP 12/15, Condition=ALL_32GSWL_SFP(TXP<=251), Current Value:[TXP, 251 uW], Rule ALL_SFP_32GSWL_TX_POWER_251 triggered 57 times in 1 day and last trigger time Thu Jun 15 16:38:27 2023, Dashboard Category=Port Health.
023/06/14-17:29:26, [MAPS-1003], 182281, SLOT 1 | FID 128, WARNING, H1NETxxx, slot12 port15, F-Port 12/15, Condition=ALL_HOST_PORTS(LR/min>1), Current Value:[LR, 2 LRs], RuleName=ALL_HOST_PORTS_LR_1_ELK, Dashboard Category=Port Health.
2023/06/14-17:30:08, [MAPS-1003], 182282, SLOT 1 | FID 128, WARNING, H1NETxxx, slot12 port15, F-Port 12/15, Condition=ALL_HOST_PORTS(LR/min>4), Current Value:[LR, 5 LRs], RuleName=ALL_HOST_PORTS_LR_4, Dashboard Category=Port Health.
2023/06/14-17:30:26, [MAPS-1003], 182283, SLOT 1 | FID 128, WARNING, H1NETxxx, slot12 port15, F-Port 12/15, Condition=ALL_HOST_PORTS(LR/min>1), Current Value:[LR, 8 LRs], RuleName=ALL_HOST_PORTS_LR_1_ELK, Dashboard Category=Port Health.          
2023/06/14-09:27:56 (IST), [MAPS-1003], 915764, SLOT 1 | FID 128 | PORT 9/42, WARNING, Brocade, slot9 port42-H.DELL_Chassis.xx.10.226.xx.xx.3F07xxx.SI, U-Port 9/42, Condition=ALL_OTHER_F_PORTS(STATE_CHG/min>5), Current Value:[STATE_CHG, 9], RuleName=defALL_OTHER_F_PORTSSTATE_CHG_5, Dashboard Category=Port Health, Quiet Time=None.
2023/06/14-09:27:56 (IST), [MAPS-1003], 915763, SLOT 1 | FID 128 | PORT 9/42, WARNING, Brocade, slot9 port42-H.DELL_Chassis.xx.10.226.xx.xx.3F07xx1.SI, U-Port 9/42, Condition=ALL_HOST_PORTS(STATE_CHG/min>5), Current Value:[STATE_CHG, 9],
RuleName= defALL_HOST_PORTSSTATE_CHG_5, Dashboard Category=Port Health, Quiet Time=None.

  • sfpshow 将低Rx功率和Tx功率报告为-INF:

=============
Slot  6/Port  8:
=============
RX Power:    -5.5    dBm (284.6uW)
TX Power:    -inf    dBm (0.0   uW)

  • sfpshow 将Tx功率报告为-inf

=============
Slot  9/Port 15:
=============
RX Power:   -1.2   dBm (751.4uW)
TX Power:   -inf   dBm (0.0   uW)

  • sfpshow 报告低Tx功率:

=============
Slot 12/Port 15:
=============
RX Power:   -2.5   dBm (556.0uW)
TX Power:   -8.4   dBm (144.1 uW)

  • Fabriclog报告链路轻拍、如下所示:

17:47:01.645590 *Removing all nodes from port         A2,P0  A2,P0  79   NA
17:47:01.645838 SCN Port F_PORT                A2,P1  A2,P0  79   NA
17:47:01.646695 SCN Port Offline;rsn=0x3,g=0x66c       A2,P0  A2,P0  79   NA
17:47:01.646703 *Removing all nodes from port         A2,P0  A2,P0  79   NA
17:47:02.439648 SCN LR_PORT(0);g=0x66c            A2,P0  A2,P0  79   NA
17:47:03.316504 SCN LR_PORT(0);g=0x66c            A2,P0  A2,P0  79   NA
17:47:03.366059 SCN Port Online; g=0x66c,isolated=0      A2,P0  A2,P1  79   NA

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.