跳转到主内容

无法访问Brocade DCX 8510-8 WWN卡

Views:
1
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade<a>2010011998.</a>
Last Updated:

适用场景

  • Brocade DCX 8510-8
  • Fabric OS (FOS) 8.2.3D版

问题描述

  • errdump 显示WWN卡的问题:
[EM-1220], 474, SLOT 7 | CHASSIS, ERROR, Brocade_DCX, A problem (Error:34) has been detected on one or both WWN cards. Please run the wwnrecover tool to get more information and recov
  • chassisshow 将WWN卡标记为无法访问的WWN卡中:
WWN  Unit: 2*
Header Version:    2
Power Consume Factor: -1W
Factory Part Num:    60-1003060-01
Factory Serial Num:   AJXXXXXXXXX
Manufacture:      Day: 31  Month: 10  Year: 2017
Update:         Day:  1  Month:  5  Year: 2024
Time Alive:       124 days
Time Awake:       26 days
 
Chassis Factory Serial Num: AFYXXXXXXXX
* = No system control access to FRU
WWN data manager state: CF_COPY
  • slotshow WWN卡中、也无法访问:
2   WWN CARD       FLTY p=0000103 r=20008 h=00*
* = No system control access to slot.
  • FOS位于8.2.3c1或更高版本上:
firmwareshow -v:
Slot Name    Appl   Primary/Secondary Versions        Status
--------------------------------------------------------------------------
6  CP0     FOS    v8.2.3d                  STANDBY
v8.2.3d
7  CP1     FOS    v8.2.3d                  ACTIVE *
v8.2.3d
  • 显示的WWN licenseidshowwwnswitchshow 输出匹配:
sw:FID128:root> licenseidshow
10:00:88:94:71:01:23:45
sw:FID128:root> wwn
10:00:88:94:71:01:23:45
  • 运行 wwnrecover 失败:
sw:FID128:root> wwnrecover
WWN Discrepancies (Error:34) detected.
 
Please attempt recovery of these errors (where possible)
by navigating to the required recovery selection
from the following WWN Recovery Options Menu.
 
Please note that in the event of a mismatch in the LicenseIds,
between WWN1 and WWN2 cards, wwn recovery may not be possible.
In this case a factory programmed card with a matching LicenseId
must be used, as a replacement card, to complete the wwn recovery.
 
WWN Critical Seeprom 2 is Inaccessible or Corrupted.
 
WWN Seeprom Problem Details
 
WWN 2 Critical Seeprom: Read Failed.
Internal error: inconsistent WWN API return values
Recovery is not possible. Please contact Brocade Technical Support for replacement of the inaccessible WWN(s).
  • 之后问题描述仍然存在 hafailover

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.