无法访问Brocade DCX 8510-8 WWN卡
适用场景
- Brocade DCX 8510-8
- Fabric OS (FOS) 8.2.3D版
问题描述
errdump
显示WWN卡的问题:
[EM-1220], 474, SLOT 7 | CHASSIS, ERROR, Brocade_DCX, A problem (Error:34) has been detected on one or both WWN cards. Please run the wwnrecover tool to get more information and recov
- 在
chassisshow
将WWN卡标记为无法访问的WWN卡中:
WWN Unit: 2*
Header Version: 2
Power Consume Factor: -1W
Factory Part Num: 60-1003060-01
Factory Serial Num: AJXXXXXXXXX
Manufacture: Day: 31 Month: 10 Year: 2017
Update: Day: 1 Month: 5 Year: 2024
Time Alive: 124 days
Time Awake: 26 days
Chassis Factory Serial Num: AFYXXXXXXXX
* = No system control access to FRU
WWN data manager state: CF_COPY
- 在
slotshow
WWN卡中、也无法访问:
2 WWN CARD FLTY p=0000103 r=20008 h=00*
* = No system control access to slot.
- FOS位于8.2.3c1或更高版本上:
firmwareshow -v:
Slot Name Appl Primary/Secondary Versions Status
--------------------------------------------------------------------------
6 CP0 FOS v8.2.3d STANDBY
v8.2.3d
7 CP1 FOS v8.2.3d ACTIVE *
v8.2.3d
- 显示的WWN
licenseidshow
与wwn
或switchshow
输出匹配:
sw:FID128:root> licenseidshow
10:00:88:94:71:01:23:45
sw:FID128:root> wwn
10:00:88:94:71:01:23:45
- 运行
wwnrecover
失败:
sw:FID128:root> wwnrecover
WWN Discrepancies (Error:34) detected.
Please attempt recovery of these errors (where possible)
by navigating to the required recovery selection
from the following WWN Recovery Options Menu.
Please note that in the event of a mismatch in the LicenseIds,
between WWN1 and WWN2 cards, wwn recovery may not be possible.
In this case a factory programmed card with a matching LicenseId
must be used, as a replacement card, to complete the wwn recovery.
WWN Critical Seeprom 2 is Inaccessible or Corrupted.
WWN Seeprom Problem Details
WWN 2 Critical Seeprom: Read Failed.
Internal error: inconsistent WWN API return values
Recovery is not possible. Please contact Brocade Technical Support for replacement of the inaccessible WWN(s).
- 之后问题描述仍然存在
hafailover