跳转到主内容

Brocade 8510 或 DCX 光纤通道交换机可能会发生故障 加热

Views:
33
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

  • Brocade (DCX8510)
  • Brocade DCX 交换机

问题描述

 

  • Brocade DCX 或 8510 报告刀片式服务器温度过高,并且某些刀片式服务器因温度过高而标记为 ` ` 。faulty
  • 调查进一步表明,在 DCX 风扇输入处测量的数据中心环境温度不超过正常限制。
  • 更换出现故障的刀片式服务器无法解决此问题
  • 温度过高的情况仅限于几个传感器 但大多数都在可接受的范围内
  • RASLOG 将显示警告和严重错误消息:
2016/02/13-18:17:20:637749, [HIL-1501], 46454/3937, SLOT 7 | CHASSIS, WARNING, DCXa, Slot 5, high temperature (69).
2016/02/13-18:21:38:105359, [HIL-1502], 46461/3944, SLOT 7 | FFDC | CHASSIS, CRITICAL, DCXa, Slot 5, high temperature (74). Unit will be shut down in 2 minutes if temperature remains high.
2016/02/13-18:23:42:477105, [HIL-1503], 46469/3948, SLOT 7 | FFDC | CHASSIS, CRITICAL, DCXa, Slot 5, unit shutting down.
  • tempshow 命令的输出将标记在最高温度以上运行的任何组件:
DCXa:FID128:root> tempshow
Sensor  Slot    State             Centigrade     Fahrenheit
ID
========================================================
32    5     Above maximum          72            161
sensor 32: (Temperature) is Above maximum, value is 72 C
  • 如果刀片式服务器因温度过高而关闭,则它将在 slotshow 命令输出中显示为 "Faulty ( 5 ) " :


slotshow -m
Slot   Blade Type     ID    Model Name     Status
--------------------------------------------------
5     CORE BLADE   98     CR16-8         FAULTY (5)

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.