跳转到主内容

使用单个PSU的旧FOS上的Brocade 6505在映射中报告bad_fan (边缘)

Views:
13
Visibility:
Public
Votes:
0
Category:
fc-series<a>2009650431</a>
Specialty:
san
Last Updated:

适用场景

  • Brocade 6505 
  • Fabric OS (FOS) v8.0.0或更低版本
  • 电源设备(PSU)

问题描述

  • 具有单个PSU的Brocade 6505正在向 风扇问题描述发出警报:
  • Errdump 警报:

2022/12/14-10:52:00, [MAPS-1021], 35, FID 128, WARNING, switch1, RuleName=defCHASSISBAD_FAN_MARG, Condition=CHASSIS(BAD_FAN>=1), Obj:Chassis [ BAD_FAN,1] has contributed to switch status MARGINAL.

  • mapsdb --show  将状态更改为 MARGINAL

switch1:admin> mapsdb --show
Current Switch Policy Status: MARGINAL
Contributing Factors:
---------------------
*BAD_FAN (MARGINAL).
[...]

  • psshow 和的输出 fanshow 符合预期:

/fabos/cliexec/psshow:
Power Supply #1 is OK
Power Supply #2 is absent

/fabos/cliexec/fanshow:
Fan 1 is Ok, speed is 8653 RPM
Fan 2 is Absent

  •  对于单个PSU交换机、交换机状态策略符合预期。 
switch.status.policy.PowerSupplies.down = 2
switch.status.policy.PowerSupplies.marginal = 0
switch.status.policy.Fans.down:2
switch.status.policy.Fans.marginal:0

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • 这篇文章对您有帮助吗?