使用单个PSU的旧FOS上的Brocade 6505在映射中报告bad_fan (边缘)
适用场景
- Brocade 6505
- Fabric OS (FOS) v8.0.0或更低版本
- 电源设备(PSU)
问题描述
- 具有单个PSU的Brocade 6505正在向 风扇问题描述发出警报:
Errdump
警报:
2022/12/14-10:52:00, [MAPS-1021], 35, FID 128, WARNING, switch1, RuleName=defCHASSISBAD_FAN_MARG, Condition=CHASSIS(BAD_FAN>=1), Obj:Chassis [ BAD_FAN,1] has contributed to switch status MARGINAL.
mapsdb --show
将状态更改为MARGINAL
switch1:admin> mapsdb --show
Current Switch Policy Status: MARGINAL
Contributing Factors:
---------------------
*BAD_FAN (MARGINAL).
[...]
psshow
和的输出fanshow
符合预期:
/fabos/cliexec/psshow:
Power Supply #1 is OK
Power Supply #2 is absent
/fabos/cliexec/fanshow:
Fan 1 is Ok, speed is 8653 RPM
Fan 2 is Absent
- 对于单个PSU交换机、交换机状态策略符合预期。
switch.status.policy.PowerSupplies.down = 2
switch.status.policy.PowerSupplies.marginal = 0
switch.status.policy.Fans.down:2
switch.status.policy.Fans.marginal:0