跳转到主内容

插槽上的交换机端口将变为Hard_Flt状态、并在errdump下观察到DMA错误

Views:
65
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade<a>2008841243</a><a>进行翻译</a>
Last Updated:

适用场景

  • Brocade 交换机
  • 所有 FOS 版本

问题描述

插槽上的多个交换机端口处于Hard_Flt状态、并在错误转储下观察到DMA错误

2021/07/16-16:29:15:850626, [C4-5057], 86137/0, SLOT 1 | CHASSIS, ERROR, SWITCH_X6-4, DMA corrupt desc: Chip[OID 0x43410080] ch: 0, desc_ptr:   0x000000cf, desc: 0x8000004f, 0x00009884, 0x7f2b4100, 0x00000000, wait: 1058364661, OID:0x43410080, c4_txrx.c, line: 4951, comp:emd, ltime:2021/07/16-16:29:15:850478

2021/07/16-16:29:17:868238, [LOG-5000], 86138/0, SLOT 1 | CHASSIS, INFO, SWITCH_X6-4, Previous message repeat 1 time(s), OID:0x43410080, c4_txrx.c, line: 4951, comp:emd, ltime:2021/07/16-16:29:16:390440

2021/07/16-16:29:17:868300, [C4-5351], 86139/0, SLOT 1 | CHASSIS, CRITICAL, SWITCH_X6-4, LKSM [OID 0x43428039] (065) (S4,BP57): Port to be faulted due to busy buffer stuck error, OID:0x43428039, proto_lksm.c, line: 1708, comp:emd, ltime:2021/07/16-16:29:17:867995

2021/07/16-16:29:17:868320, [C4-1002], 86140/71770, SLOT 1 | FFDC | CHASSIS, ERROR, SWITCH_X6-4, Port 65 chip failed due to an internal error., OID:0x43428039, proto_lksm.c, line: 1711, comp:emd, ltime:2021/07/16-16:29:17:868065

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.