跳转到主内容

VIFMGR脱机将集群交换机CN1610迁移到BES-53248

Views:
6
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
HW
Last Updated:

适用场景

  • 集群网络交换机(CNS)硬件升级
  • CN1610
  • BES-53248

问题描述

  • 多个 处于运行状态的Lifs已关闭。
  • 受影响SVM的多项服务发生停机。
  • 由于 在仍连接节点的情况下禁用了交换机之间的ISL、集群ping失败。
  • VIFMGR脱机、某些接口已迁移或运行状态为已关闭。示例:

Wed Jun 23 2021 09:27:18 +02:00 [kern_vifmgr:info:7192] [0x80bae2900] [FailoverMgr::cluster_check] 100% packet loss when pinging from node1_lif1 ( 169.254.137.239 ) on node1 -> node3_lif2 ( 169.254.16.239 ) on node3
Wed Jun 23 2021 09:27:19 +02:00 [kern_vifmgr:info:7192] [0x80bae2900] [FailoverMgr::cluster_check] l2ping failed e0a on node1 -> e0b on node3 result='remote interface is down or unreachable. If a VLAN was specified, it may not be configured on the switch.'
Wed Jun 23 2021 09:27:42 +02:00 [kern_vifmgr:info:7192] [0x80bae2900] [FailoverMgr::cluster_check] 100% packet loss when pinging from node1_lif1 ( 169.254.137.239 ) on node1 -> node4_lif2 ( 169.254.128.136 ) on node4
Wed Jun 23 2021 09:27:44 +02:00 [kern_vifmgr:info:7192] [0x80bae2900] [FailoverMgr::cluster_check] l2ping failed e0a on node1 -> e0b on node4 result='remote interface is down or unreachable. If a VLAN was specified, it may not be configured on the switch.'
Wed Jun 23 2021 09:28:07 +02:00 [kern_vifmgr:info:7192] [0x80bae2900] [FailoverMgr::cluster_check] 100% packet loss when pinging from node1_lif1 ( 169.254.137.239 ) on node1 -> node2_lif2 ( 169.254.63.209 ) on node2
Wed Jun 23 2021 09:28:08 +02:00 [kern_vifmgr:info:7192] [0x80bae2900] [FailoverMgr::cluster_check] l2ping failed e0a on node1 -> e0c on node2 result='remote interface is down or unreachable. If a VLAN was specified, it may not be configured on the switch.'
Wed Jun 23 2021 09:28:32 +02:00 [kern_vifmgr:info:7192] [0x80bae2900] [FailoverMgr::cluster_check] 100% packet loss when pinging from node1_lif1 ( 169.254.137.239 ) on node1 -> node2_lif2 ( 169.254.136.171 ) on node2
Wed Jun 23 2021 09:28:33 +02:00 [kern_vifmgr:info:7192] [0x80bae2900] [FailoverMgr::cluster_check] l2ping failed e0a on node1 -> e0c on node2 result='remote interface is down or unreachable. If a VLAN was specified, it may not be configured on the switch.'
...
Wed Jun 23 2021 09:35:03 +02:00 [kern_vifmgr:info:6719] [0x80b970b00] [Net::RdbLifHandle::avoidDownPorts] LIF lif:rdb:4294967293:node2_lif2 (947) is assigned to a down port (node2:e0c). Attempting to reassign.
...
Wed Jun 23 2021 09:35:14 +02:00 [kern_vifmgr:info:6719] A [src/rdb/TM.cc 1760 (0x80bf51600)]: _triggerOnlineStatusCallback: FAILOVER rdb: Local unit VifMgr offline
Wed Jun 23 2021 09:35:14 +02:00 [kern_vifmgr:info:6719] Notice: online_status_callback: RDB unit is offline
...
Wed Jun 23 2021 09:35:14 +02:00 [kern_vifmgr:info:6719] [0x80b970b00] [EventMgr::workerThreadMain] received port table update while OFFLINE
...
Wed Jun 23 2021 09:35:18 +02:00 [kern_vifmgr:info:6719] A [src/rdb/TM.cc 1787 (0x810d52700)]: _triggerOnlineStatusCallback: FAILOVER rdb: Local unit VifMgr online
Wed Jun 23 2021 09:35:18 +02:00 [kern_vifmgr:info:6719] A [src/rdb/cluster_events.cc 88 (0x810d52700)]: Report: Cluster event: node-event, epoch 19, site 1007 [local node online (secondary)].
Wed Jun 23 2021 09:35:18 +02:00 [kern_vifmgr:info:6719] Notice: online_status_callback: RDB unit is online as Secondary

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.