已针对BES-53248集群交换机报告SwitchIfIlDownWarn_Alert
适用场景
- ONTAP 9
- BES-53248集群交换机
问题描述
- 事件日志中会针对BES-53248集群交换机报告以下警报:
[Node-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchIfIslDownWarn_Alert[CLUSW01/Slot: 0 Port: 55 100G - Level].
- 由于此问题描述 、交换机运行状况已降级:
Cluster::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster
ok
13 entries were displayed.
- 两个集群交换机上报告的ISL端口的状态均为已关闭:
CLUSW01# show port all
Admin Physical Physical Link Link LACP Actor
Intf Type Mode Mode Status Status Trap Mode Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/55 PC Mbr Enable 100G Full Down Enable Enable long
0/56 PC Mbr Enable 100G Full 100G Full Up Enable Enable long
- 连接到ISL端口的缆线出现错误:
CLUSW01# show fiber-ports optical-transceiver-info all
Link Link Nominal
Length Length Link Bit Rate
Number 50um 62.5um Length Per Lane
Port of Lanes Vendor Name [m] [m] [m] Serial Number Part Number [Mbps] Rev Compliance
------ -------- ---------------- --- ---- ------ ---------------- ---------------- ----- ---- ----------------
0/55 4 Molex 0 0 1M 93AXXXXXX0028 112-00573 25500 B0 100GBase-CR4