适用场景

  • Brocade X7交换机
  • FOS v9.2.1a

问题描述

  • Brocade X7 交换机上的备用 CP 已重启。
  • 备用 CP 进入故障状态,并返回到无效状态。

2025/04/28-02:03:56 (IST), [HAMK-1004], 2352808, SLOT 1 | CHASSIS, INFO, sw13, Resetting standby CP (double reset may occur).
2025/04/28-02:03:56 (IST), [FSSM-1003], 2352809, SLOT 1 | CHASSIS, WARNING, sw13, HA State out of sync.
2025/04/28-02:03:56 (IST), [EM-1033], 2352810, SLOT 1 | CHASSIS, ERROR, sw13, CP in Slot 2 set to faulty because CP ERROR asserted.
2025/04/28-02:03:59 (IST), [EM-1047], 2352811, SLOT 1 | CHASSIS, INFO, sw13, CP in slot 2 not faulty, CP ERROR deasserted.
2025/04/28-02:04:22 (IST), [MAPS-1021], 2352812, SLOT 1 | FID 128, WARNING, sw1, RuleName=defCHASSISHA_SYNC_0, Condition=CHASSIS(HA_SYNC/NONE==0), Obj:Chassis [HA_SYNC,0] has contributed to switch status MARGINAL.
2025/04/28-02:04:22 (IST), [MAPS-1020], 2352813, SLOT 1 | FID 128, WARNING, sw1, Switch wide status has changed from HEALTHY to MARGINAL.

  • 备用包上的二级分区显示为 Vpackage。

firmwareshow -v:
Slot Name     Appl    Primary/Secondary Versions         Status
--------------------------------------------------------------------------
  1  CP0     FOS    v9.2.1a                  ACTIVE
             v9.2.1a                  
  2  CP1     FOS    v9.2.1a                  STANDBY *
             vpackage                 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.