跳转到主内容

集群交换机重新启动后ISL关闭

Views:
1
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • BES-53248群集交换机

问题描述

  • 交换机重新启动后,系统会 在事件日志中报告ClusterifIslDownWarn_Alert 警报

Thu Aug 03 06:57:42 -0400 [node-03: mgwd: callhome.hm.alert.major:debug]: Call home for Health Monitor process cshm: ClusterIfIslDownWarn_Alert[node03sw01/ Link Aggregate 1].

  • 活动系统运行状况警报如下所示

tpanetapp08::> system health alert show
               Node: Node-03
           Alert ID: ClusterIfIslDownWarn_Alert
           Resource:  Link Aggregate 1
           Severity: Major
  Indication Time: Thu Aug 03 07:12:08 2023
           Suppress: false
        Acknowledge: false
     Probable Cause: The cable used to connect switch tpanetapp08sw01/
                     Link Aggregate 1 to the ISL port might be faulty. For
     the port-channel

  • 集群ISL报告已关闭

0/55      PC Mbr Enable    100G Full             Down   Enable  Enable long
0/56      PC Mbr Enable    100G Full             Down   Enable  Enable long

Log.    Channel                     Admin       Mbr     Device/       Port      Port
Intf    Name            Min  Link   Mode   Type Ports   Timeout       Speed     Active
------- --------------- ---- ------ ------ ---- ------- ------------- --------- -------
1/1     Cluster-ISL     1   Down   En.    Dyn. 0/55    actor/long    100G Full False
                                                        partner/long
                                                0/56    actor/long    100G Full False
                                                        partner/long

  • 如果对ISL端口进行了故障转移、则这些端口仍会关闭

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.