跳转到主内容

Brocade交换机显示电源出现故障

Views:
82
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

Brocade 交换机

问题描述

  • 交换机PSU上显示琥珀色指示灯或没有链路指示灯。
  • sensorshow 将PSU2报告为“FABHE故障”,将风扇2报告为“未知”。 

sensorshow     :
sensor  1: (Temperature) is Ok, value is 39 C
sensor  2: (Fan 1 ) is Ok,speed is 6617 RPM
sensor  3: (Fan 2 ) is Unknown
sensor  4: (Power Supply) is Ok
sensor  5: (Power Supply) is Faulty

  • psshow 报告电源2 出现故障

psshow     :

Power Supply #1 is OK
Power Supply #2 is faulty

  • fanshow 将风扇 2报告为 未知

fanshow     :
Fan 1 is Ok, speed is 6617 RPM
Fan 2 is Unknown

  • 如所示 errdump,可以看到PS1、 ps2和fan2出现故障:

2023/06/21-14:13:39, [EM-1034], 88278, CHASSIS, ERROR, Brocade, PS 2 set to faulty, rc=2000e.
2023/06/21-14:13:41, [FW-1010], 88279, FID 128, WARNING, Brocade, Env Power Supply 2, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY).
2023/06/21-14:13:41, [FW-1424], 88280, FID 128, WARNING, Brocade, Switch status changed from HEALTHY to MARGINAL.
2023/06/21-14:13:41, [FW-1427], 88281, FID 128, WARNING, Brocade, Switch status change contributing factor Power supply: 1 bad.

2023/06/21-14:13:56, [EM-1034], 88293, CHASSIS, ERROR, Brocade, PS 1 set to faulty, rc=2000e.
2023/06/21-14:14:00, [FW-1010], 88294, FID 128, WARNING, Brocade, Env Power Supply 1, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY).
2023/06/21-14:14:00, [FW-1424], 88295, FID 128, WARNING, Brocade, Switch status changed from HEALTHY to MARGINAL.
2023/06/21-14:14:00, [FW-1427], 88296, FID 128, WARNING, Brocade, Switch status change contributing factor Power supply: 1 bad.
2023/06/21-14:14:00, [EM-1037], 88298, CHASSIS, INFO, Brocade, PS 1 is no longer faulted.

2023/06/21-14:23:40, [HIL-1610], 88315, CHASSIS, WARNING, Brocade, Fan/PS unit 2 not supplying power, fan speeds may not be available. Please ensure that the unit has power and the switch is on.
2023/06/21-14:23:44, [FW-1431], 88316, FID 2, WARNING, Brocade, Switch status change contributing factor Fan: 1 bad.
2023/06/21-14:23:46, [FW-1431], 88317, FID 128, WARNING, Brocade, Switch status change contributing factor Fan: 1 bad

 

  • 在更换交换机PSU之前、请按照以下步骤进一步排除站点上的任何潜在电源问题、例如电源插座、电缆等:
  1. 检查电源线是否连接正确。
  2. 尝试换用已知良好的电源线。
  3. 重新拔插交换机的电源线和PSU。
  4. 确保外部电源正常运行。

 

注:对于Brocade 6510交换机、风扇集成在电源设备中

发生原因


电源故障

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.