跳转到主内容

Brocade 交换机显示电源故障

Views:
133
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用于

Brocade 交换机

问题描述

  • 交换机 PSU 上显示琥珀色指示灯或无链路指示灯
  • 使用 chassisshow 检查
  • sensorshow 报告 PSU2 为"故障",风扇 2 为"未知"。 

sensorshow     :
sensor  1: (Temperature) is Ok, value is 39 C
sensor  2: (Fan 1 ) is Ok,speed is 6617 RPM
sensor  3: (Fan 2 ) is Unknown
sensor  4: (Power Supply) is Ok
sensor  5: (Power Supply) is Faulty

  • psshow 将 Power Supply 2 报告为故障

psshow     :

Power Supply #1 is OK
Power Supply #2 is faulty

  • fanshow 将 Fan 2 报告为未知

fanshow     :
Fan 1 is Ok, speed is 6617 RPM
Fan 2 is Unknown

  • 根据 errdump,可以看到 PS1、PS2 和 Fan2 都出现故障:

2023/06/21-14:13:39, [EM-1034], 88278, CHASSIS, ERROR, Brocade, PS 2 set to faulty, rc=2000e.
2023/06/21-14:13:41, [FW-1010], 88279, FID 128, WARNING, Brocade, Env Power Supply 2, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY).
2023/06/21-14:13:41, [FW-1424], 88280, FID 128, WARNING, Brocade, Switch status changed from HEALTHY to MARGINAL.
2023/06/21-14:13:41, [FW-1427], 88281, FID 128, WARNING, Brocade, Switch status change contributing factor Power supply: 1 bad.

2023/06/21-14:13:56, [EM-1034], 88293, CHASSIS, ERROR, Brocade, PS 1 set to faulty, rc=2000e.
2023/06/21-14:14:00, [FW-1010], 88294, FID 128, WARNING, Brocade, Env Power Supply 1, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY).
2023/06/21-14:14:00, [FW-1424], 88295, FID 128, WARNING, Brocade, Switch status changed from HEALTHY to MARGINAL.
2023/06/21-14:14:00, [FW-1427], 88296, FID 128, WARNING, Brocade, Switch status change contributing factor Power supply: 1 bad.
2023/06/21-14:14:00, [EM-1037], 88298, CHASSIS, INFO, Brocade, PS 1 is no longer faulted.

2023/06/21-14:23:40, [HIL-1610], 88315, CHASSIS, WARNING, Brocade, Fan/PS unit 2 not supplying power, fan speeds may not be available. Please ensure that the unit has power and the switch is on.
2023/06/21-14:23:44, [FW-1431], 88316, FID 2, WARNING, Brocade, Switch status change contributing factor Fan: 1 bad.
2023/06/21-14:23:46, [FW-1431], 88317, FID 128, WARNING, Brocade, Switch status change contributing factor Fan: 1 bad

  • 在更换交换机 PSU 之前,请按照以下步骤进一步排除现场任何潜在的电源问题,如电源插座、电缆等:
  1. 检查电源线是否连接正确。
  2. 尝试使用已知良好的电源线进行更换。
  3. 重新插拔交换机的电源线和 PSU。
  4. 确保外部电源正常运行。

发生原因


电源故障

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.