适用场景

  • 集群网络交换机型号BES-53248
  • Broadcom以太网光纤操作系统(EFOS)   3.9.0.2、 3.11.1.2版
  • 参考配置文件(RCF) v1.9
  • MetroCluster IP RC框架2.11版
  • 100GbE端口

问题描述

  • 100GbE上的一个许可网络集群端口(49到54)在交换机端发生轻拍。
    示例 
Switch-1 TRAPMGR[trapTask]: traputil.c(753) 4810741 %% NOTE SFP removed from 0/49
Switch-1 DOT1S[dot1s_task]: dot1s_control.c(3088) 4810740 %% INFO Stopping SM on 49
Switch-1 TRAPMGR[trapTask]: traputil.c(753) 4810739 %% NOTE Link Down: 0/49, Reason Code: 0x40
Switch-1 TRAPMGR[trapTask]: traputil.c(753) 4810735 %% NOTE Link Up: 0/49
Switch-1 TRAPMGR[trapTask]: traputil.c(753) 4810732 %% NOTE Link Down: 0/49, Reason Code: 0x40
Switch-1 DOT1S[dot1s_task]: dot1s_control.c(3088) 4810731 %% INFO Stopping SM on 49
Switch-1 TRAPMGR[trapTask]: traputil.c(753) 4810727 %% NOTE Link Up: 0/49
Switch-1 DOT1S[dot1s_task]: dot1s_control.c(3088) 4810724 %% INFO Stopping SM on 49
  • 为连接到该交换机端口的节点端口报告的后续ONTAP事件消息: 
[Node01: intr: netif.linkDown:info]: Ethernet xxx: Link down, check cable.
[Node01: vifmgr: vifmgr.portdown:debug]: A link down event was received on node Node01, port xxx.
[Node01: vifmgr: vifmgr.clus.linkdown:debug]: The cluster port xxx on node Node01 has gone down unexpectedly.
[Node01: intr: netif.linkUp:info]: Ethernet xxx: Link up.
[Node01: vifmgr: vifmgr.portup:debug]: A link up event was received on node Node01, port xxx.
  • 接口0/49 设置为自动协商:
(Switch-01)#show port 0/49
         Admin   Physical  Physical  Link  Link   LACP  Actor
Intf    Type  Mode    Mode    Status   Status Trap   Mode  Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/49       Enable   Auto    100G Full Up   Enable  Enable long
  • 在交换/更换缆线和SFP后、问题描述仍然存在。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.