BES-53248交换机无法使用EFOS而是ONIE启动

Views:
6
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

适用场景

Broadcom以太网交换机53248 (BES-53248)

问题描述

  • BES-53248集群交换机 在关闭电源后无法启动至EFOS。
    • 这将与维护活动、环境问题描述等相关
  • 启动设备缺少EFOS选项。示例: 

+----------------------------------------------------------------------------+
|*ONIE: Install OS                               |
| ONIE: Rescue                                 |
| ONIE: Uninstall OS                              |
| ONIE: Update ONIE                              |
| ONIE: Embed ONIE                               |
| DIAG: Diagnostic Mode                            |
| DIAG: Burn-In Mode                              |
|                                       |
|                                       |
|                                       |
|                                       |
+----------------------------------------------------------------------------+

  • 从BES交换机输出中、报告了与P(3V (实时时钟电池)相关的低电压的问题描述。示例

(switch_name)# linuxsh

# ipmitool sel elist
 ...
 123 | 01/01/2025 | 01:01:01 | Voltage Volt_P3V_BAT | Lower Critical going low  | Asserted | Reading 0.54 < Threshold 2.53 Volts

# ipmitool sensor
...
Volt_P3V3_SUS    | 3.308      | Volts      | ok    | na        | 2.975     | na        | na        | 3.623     | na
Volt_P3V_BAT     | 1.793      | Volts      | cr    | na        | 2.528     | na        | na        | 3.616     | na

# ipmitool sdr
...
Volt_P3V3_SUS    | 3.31 Volts        | ok
Volt_P3V_BAT     | 1.79 Volts        | cr

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.