跳转到主内容

SF系列节点硬件故障:集群UI中的RTFI或timeToChargeCapac器 出现RTFI_hardware_failures RADIAN_time_to_charge或timeToChargeCapac器 出现:{>150}

适用场景

  • SF 系列存储节点

问题描述

  • 在存储集群UI中、节点故障:
    • nvramDeviceStatus
    • NVRAM device problems detected, metadata drive will be removed. Contact NetApp Support. warning={timeToChargeCapacitors: [>150] Seconds} error={derivedCapacitanceOfThePack: 0.000 F}

  • 在RTFI期间:
    • There were 1 hardware related RTFI_HARDWARE_FAILURES
    • RADIAN_TIME_TO_CHARGE

RTFI期间的屏幕截图示例:

clipboard_e5d06fa689232c8f39fc3ae4c601fa623.png

 

  • 如果在RTFI期间发生这种情况、请接受此消息 Ignore errors and continue (ALT-F8 to display, ALT-F7 to return) (Yes,No)
  • 完成RTFI并将节点添加到集群中、但不要添加任何驱动器
  • 集群UI应显示类似于以下内容的节点故障:
    • NVRAM device problems detected, metadata drive will be removed. Contact NetApp Support. error={derivedCapacitanceOfThePack: 0.000 F, timeToChargeCapacitors: 42949664 Seconds}

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.