跳转到主内容

由于 CPU 问题,节点关闭

Views:
19
Visibility:
Public
Votes:
0
Category:
sf-series
Specialty:
solidfire
Last Updated:

适用场景

  • NetApp SolidFire SF 系列
  • Element 软件版本 12.2.0.777

问题描述

  • 节点意外关闭,未自动重新启动
  • iDRAC 显示错误CPU x(id) has an internal error (IERR)
  • ipmitool 从远程服务器(例如管理节点 VM )执行的命令确认断言的处理器错误:
    • 命令:ipmitool -H BMC_IP_ADDRESS -U bmc_username -I lan sel list
    • 输出示例:
      ID | DATE | TIME | Processor #0x60 | IERR | Asserted
    • 命令:ipmitool -H BMC_IP_ADDRESS -U bmc_username -I lan sel list -v
    • 输出示例:
      SEL Record ID : ID
       Record Type : 02
       Timestamp : DATE TIME
       Generator ID : 0020
       EvM Revision : 04
       Sensor Type : Processor
       Sensor Number : 60
       Event Type : Sensor-specific Discrete
       Event Direction : Assertion Event
       Event Data : 00ffff
       Description : IERR

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.